** Refer to Quick Selection Chart for specific furnace match-up.

HEATING CAPACITY - With Air Handler

UNIT MODEL

AIR HANDLER

MODEL

COIL

1

MODEL

W

HEATING

STAGE

RATED

CFM

NET MBH

HSPF

COP @ 47

47 OD

17 OD

18 SEER HP WITH MV - VARIABLE SPEED

YZH02411

MV12B FC/MC43B 17

1 645

19.3 -

-

4.0

2 835

24.0

17.0

9.6 4.0

2 645

24.0

15.2

9.3 3.4

MV12D FC/MC48D 24

1 645

19.3 -

-

4.0

2 835

24.0

16.8

9.8 4.0

2 645

24.0

15.0

9.5 3.4

MV12D FC/MC60D 24

1 645

19.3 -

-

4.0

2 835

24.0

16.8

9.8 4.0

2 645

24.0

15.0

9.5 3.4

YZH03611

MV16C FC/MC43C 21

1 775

26.4 -

-

4.2

2 1200

36.0

25.8 10 4.4

2 775

36.0

24.0

9.7 3.4

MV16C FC/MC48C 21

1 775

26.4 -

-

4.2

2 1200

36.0

25.8 10 4.4

2 775

36.0

24.0

9.7 3.4

MV12D FC/MC48D 24

1 845

26.4 -

-

4.2

2 1245

36.0

25.8 10 4.4

2 845

36.0

24.0

9.7 3.4

MV12D FC/MC60D 24

1 845

26.4 -

-

4.2

2 1245

36.0

25.8 10 4.4

2 845

36.0

24.0

9.7 3.4

MV12D FC/MC62D 24

1 845

26.4 -

-

4.2

2 1245

36.0

25.8 10 4.4

2 845

36.0

24.0

9.7 3.4

YZH04811

MV16C FC/MC48C 21

1 1000

35.6 -

-

3.6

2 1600

48.0

32.6 9.3 3.8

2 1000

38.0

25.4 9 3.0

MV20D FC/MC48D 24

1 1045

36.0 -

-

3.6

2 1570

48.0

32.6 9.3 3.8

2 1045

38.0

25.6 9 3.0

MV20D FC/MC60D 24

1 1045

36.0 -

-

3.8

2 1570

48.0

32.4 9.8 4.0

2 1045

38.5

25.8 9.5 3.2

MV20D FC/MC62D 24

1 1045

35.8 -

-

3.8

2 1570

48.0

32.0 9.8 4.0

2 1045

38.0

25.0 9.5 3.2

YZH06011

MV20D FC/MC60D 24

1 1175

43.0 -

-

3.4

2 1820

58.0

39.5 9.3 3.8

2 1175

46.5

27.4 9 3.0

MV20D FC/MC62D 24

1 1175

43.0 -

-

3.4

2 1820

58.0

39.0 9.3 3.8

2 1175

46.0

27.0 9 3.0

18 SEER HP WITH AV/SV - VARIABLE SPEED

YZH02411

AV36 -

21

1 600

19.2 -

-

3.8

2 765

24.0

16.9

9.6 4.0

2 600

24.0

15.1

9.3 3.2

YZH03611

AV36 -

21

1 830

26.5 -

-

4.2

2 1270

36.0

26.6 9.6 4.2

2 830

36.0

24.4

9.3 4.2

AV/SV48 -

24

1 910

27.0 -

-

4.6

2 1190

36.0

26.2 10 4.6

2 910

36.0

24.4

9.7 3.6

YZH04811

AV/SV48 -

24

1 1135

36.2 -

-

4.0

2 1610

48.0

32.4 9.8 4.0

2 1135

38.5

25.6 9.5 3.4

AV/SV60 -

24

1 1085

36.0 -

-

4.0

2 1655

48.0

32.6 9.8 4.0

2 1085

39.0

25.8 9.5 3.4

YZH06011

AV/SV60 -

24

1 1145

43.0 -

-

3.6

2 1765

58.0

39.4 9.3 3.8

2 1145

46.5

27.2 9 3.0

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8

0°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.

1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.