beautypg.com

Kp, define password, Define password – Zebra S4M User Manual

Page 118

background image

ZPL II Commands
^KP

112

13290L-001 Rev. A

S4M User Guide

10/21/05

^KP

Define Password

Description The

^KP

command is used to define the password that must be entered to

access the control panel switches and LCD Setup mode. For more information about the
password structure in this printer, see

Password Protection of Parameters on page 54

.

Format

^KPa,b

This table identifies the parameters for this format:

Password-Protect All Parameters To password protect all parameters, send the

^KP

ZPL II command with a password for each level.

Disable Passwords To disable the password-protection feature for a particular level and
those below it, set the password to 0000 using the

^KP

ZPL II command. To reenable the

password-protection feature, send the ZPL II command with any non-zero number for a
password.

Return to Default Passwords If you forget your passwords, the printer can be returned to
the default factory settings, which makes the default passwords valid again. Use caution when
returning the passwords to their default values because this also sets all other printer
parameters back to their defaults.

To return the printer to the default factory settings using ZPL, send this command:

^XA
^JUF
^XZ

Parameters

Details

a

= mandatory four-digit

password

A password of 0000 for any level disables password checking for that level and
all levels below it. The printer web pages assume the Level 3 password.
Accepted Values: Any four-digit number from 0000 to 9999
Default Value:

• Level 4—

9999

• Level 3—

1234

• Level 2—

0000

• Level 1—

0000

b = password level

Accepted Values: 1, 2, 3, 4
Default Value: 3

Example •

This example shows how to set a password of

5678

for level 3:

^XA
^KP5678,3
^XZ