Troubleshooting the 10/100 PS
Defaulting the 10/100 PS
To default the 10/100 Internal PS to factory settings using the control panel,
complete these steps:
1.
From the control panel, press
Setup/Exit
two times
.
2.
Press
Plus (+ key)
five times.
The control panel will read
DEFAULT NET.
3.
Press
Setup/Exit
to save the change.
4.
After the printer defaults all settings, the control panel will show
PRINTER READY.
10/100 Internal PS Network Status/Activity Indicator
A single LED containing a red element and a green element. By turning on and off different
combinations of these two LED elements indicate Ethernet links, activity, and speed.
ZebraNet View Utility Discovery or Configuration Problems
If you are having problems using the ZebraNet View utility to discover or configure the unit,
check the following:
• Verify there is not a router between the workstation running ZebraNet View and the
10/100 Internal PS. Because the 10/100 Internal PS does not have an IP address, TCP/IP
communication cannot be started across a router. Run ZebraNet View on the same subnet
as the 10/100 Internal PS.
• Verify that the LED on the 10/100 Internal PS is active. Consult the chart above for
details.
LED State
Description
Off
No Ethernet link detected
Green
100 Mbps link detected
Green, flickering off and on
100 Mbps link detected and Ethernet activity detected
Amber
10 Mbps link detected
Amber, flickering off and on
10 Mbps link detected and Ethernet activity detected