Hi ac volt, Hi ac freq, Hi ac volt –26 hi ac freq –26 – Xantrex Technology MS2000 User Manual
Page 80
Configuration
3–26
975-0125-02-01
Outcome
The lower frequency of voltage that will be qualified as “good” by the inverter/
charger can be varied.
Hi AC Volt
Full name
Hi AC transfer voltage (AC over voltage level)
Configurable setting
This setting lets you adjust the voltage above which the inverter/charger no longer
qualifies AC as “good” and attempts to transfer to Invert.
When to use
This setting lets you adjust the AC parameters when AC supply is outside the
upper voltage range required for electrical equipment.
Outcome
The upper level of voltage that will be qualified as “good” by the inverter/charger
can be varied.
Hi AC Freq
Full name
Hi AC transfer frequency (AC over frequency level)
Configurable setting
This setting lets you adjust the frequency at which the MS2000 no longer qualifies
AC as “good” and attempts to transfer to Invert.
When to use
This setting lets you adjust the AC parameters when the AC supply is outside the
higher frequency range required for electrical equipment.
Outcome
The higher frequency of voltage that will be qualified as “good” by the inverter/
charger can be varied.
Hi AC Volt
[135V]
Range of values
Increment
Default
120 to 145 VAC
1 volt
135 VAC
Hi AC Freq
[65Hz]
Range of values
Increment
Default
62 to 70 Hz
1 Hz
65 Hz