Environmental specifications, Physical specifications with projections, Regulatory approvals – Xantrex Technology MS2000 User Manual
Page 103: Fan operation, Regulatory approvals fan operation
Specifications
975-0125-02-01
A–5
Environmental Specifications
Table A-5 Environmental Specifications
Physical Specifications with Projections
Table A-6 Physical Specifications
Regulatory Approvals
Fan Operation
The internal cooling fans are automatic temperature-controlled.
The bottom fan is an exhaust fan and runs continuously.
Nominal Ambient temperature
77 °F (25 °C)
Full Power Operating Ambient
Temperature Range
–4 ° to 122 °F (–20 ° to 50 °C)
Maximum Operating Temperature
140 °F (60 °C)
Storage temperature range
–40 ° to 185 °F (–40 to 85 °C)
Humidity: Operation/Storage
≤
95% RH, non-condensing
Length
16.19 inches (411 mm)
Width
14.20 inches (361 mm)
Height
8.17 inches (208 mm)
Weight
67 lbs (30 kg)
DC terminal bolt size
3/8 inch
Ground terminal bolt size
1/4 inch
Safety
CSA certified to CSA C22.2 No. 107.1 and UL 458 (including Marine
Supplement)
EMC
FCC Part 15B and Industry Canada Class B
Designed to ABYC recommended practices E-11 and A-25 for marine use
Important:
This internal temperature of the inverter/charger may be caused
by heat in the inverter/charger or by high ambient temperature.