Sub-menus, Lo dc volt, Batt type – Xantrex Technology MS2000 User Manual
Page 76: Batt size, Sense below, Sub-menus –22

Configuration
3–22
975-0125-02-01
Sub-Menus
Configure Inv/Chg Menu (Configure Inverter/Charger Menu)
Cfg/Inv Chg is a sub-menu. If selected, a list of sub-menu items appears.
Lo DC Volt
Full name
Low DC input voltage shutdown
Configurable setting
This setting lets you set the low voltage shutdown level for the inverter.
When to use
This setting limits the depth of discharge on your house battery bank.
Batt Type
See a description of this feature on page 3–15.
Batt Size
See a description of this feature on page 3–15.
Sense Below
Configurable setting
This setting lets you set the threshold for load sense power. This setting saves
battery consumption by keeping the inverter disabled (turned off) except when
load demand is present.
When to use
Adjust this setting to control the inverter based on the load.
Outcome
Sets the load threshold at a power level where you want the inverter to stay on, for
example, when a sufficient load is applied.
Lo DC Volt
[10.0V]
Range
Increment
Default
10 to 13 volts
0.1 volt
10 volts
Sense Below
[50W]
Range of values
Increment
Default
40 watts to 150 watts 10 watts
50 watts