Configuration
975-0125-02-01
3–23
Sense Interval
Configurable setting
This setting lets you adjust the interval of load sensing. The longer the interval,
the more power you will save. However, the longer intervals may cause delays in
the inverter power up and starting your loads.
Cfg AC Limits (Configure AC Limits)
Cfg AC Limits is a sub-menu. If selected, a list of sub-menu items appear. For
more information on this sub menu, Configure AC Limits, see page 3–25.
# Chg Stages
Full name
Number of charge stages
Configurable setting
These settings let you adjust the charger stages of your
house battery bank to
either two-stage charging or three-stage charging.
See
Reference for the Main Charger” on page B–1
for an explanation of two-stage and
three-stage charging.
Sense Interval
[1s]
Range of values
Increment
Default
1 second to 25
seconds
1 second
1 second
# Chg Stages
[3Stage]
Value
Default
2StgNoFloat
3Stage
3Stage
Important:
The Echo Charger is not affected by this setting.