Start-up checklist

Long element T&P relief valve is properly installed and drain discharge is directed away

from all persons.

Both inner and outer tanks are filled with water.

All air has been bled from both domestic and boiler water systems.

Automatic air vent is installed and cap is unscrewed one full turn.

Cold and hot water lines are correctly connected to domestic water system.

Supply and return piping from boiler is correctly connected to water heater.

All wiring is installed correctly.

Thermostat on water heater is set according to system requirements. See pages 18–19.

Boiler and water heater are operating properly.

Fittings and piping have been checked for leaks.

Installer has reviewed the following sections with system maintainer:

Water Heater Start-Up

Adjusting Water Heater Temperature

Water Heater Maintenance