Page 12: Drain valve

background image

12

Part Number PLUS-E017-A/1206

PLUS LINE

Indirect-Fired Water Heaters – Series 3

Figure 5

Piping —

OPTION 2

PLUS 100/110/119
(Required for Commonwealth of
Massachusetts)

Drain valve

PLUS 100/110/119

Option 2

Apply the following and Figure to water heaters installed in Massachusetts. The drain valve

is mounted in the AUX tapping on top of the water heater.

1. Insert an open-ended “draining” dip tube into the AUX tapping on top of the heater.

2. Connect a elbow to the AUX tapping, using suitable pipe dope or tape.

. Pipe the drain valve to the elbow, using suitable pipe dope or tape, as shown in Figure .

. Pipe the T & P relief valve in the run of the brass tee, located in the domestic water outlet

piping as shown in Figure .

. Obtain brass tee and drain valve from local supplier.

Water heater piping

continued

A2

An expansion tank may be required on

the DHW piping. See Thermal expan-

sion

WARNING

on page 1. Failure to

comply could result in severe personal

injury, death or substantial property

damage.

When the water supply pressure is higher than 0 psig, install a pressure-reducing valve on the cold water supply

line to prevent leakage from the T & P relief valve.