beautypg.com

Water heater piping, Manual, Drain valve – Weil-McLain PLUS LINE PLUS-E017-A/1206 User Manual

Page 11

background image

Part Number PLUS-E017-A/1206

11

Manual

• Installation • Start-Up • Usage • Maintenance • Parts

Figure 4

Piping —

OPTION 1

PLUS 100/110/119
(See Figure 5, page 12, for OPTION 2,
required for Massachusetts)

Drain valve

PLUS 100/110/119

Option 1

Apply the following and Figure to water heaters other than those installed in Massachusetts.

For Commonwealth of Massachusetts installations, see Option 2, Figure , page 11.

1. Install a brass tee in the domestic water inlet piping using suitable pipe dope or tape, located

as shown in Figure .

2. Pipe the drain valve off of the brass tee as shown in Figure , using suitable pipe dope or tape.

. For jurisdictions requiring a vacuum breaker, use the piping shown in Figure , page 11

(Option 2).

. Obtain brass tee and drain valve from local supplier.

An expansion tank may be required on

the DHW piping. See Thermal expan-

sion

WARNING

on page 1. Failure to

comply could result in severe personal

injury, death or substantial property

damage.

Water heater piping

continued

A2

When the water supply pressure is higher than 0 psig, install a pressure-reducing valve on the cold water supply

line to prevent leakage from the T & P relief valve.