Westinghouse SE 6000 User Manual
Page 81

4-30
S
ECTION
4: M
ASTER
F
ILE
E
NTRY
$
PIN Timeout. Optional. The maximum amount of time, in seconds, which can pass between
the presentation of a key and the entry of a verification PIN. Default is 10.
%
Max Inv. PINs. Optional. The maximum number of invalid PIN entry attempts to permit
before cancelling the key presentation. Default is 4.
&
VIPs Digits. Optional. The number of digits in the PIN number for doors using keypads only.
The range is 4 to 8. Default is 4.
'
Modem Definition. Not used when the SE 6000 is connected directly or in a dial-up
configuration.
Latched Contact. Optional. The number of the output contacts that are assigned as a
latched contact (0—51). Default is 0.
ABA Site Code Grp. Optional. The ABA site code group ID number.
EMPI Alt1 Code. Optional. Alternate EMPI site code #1.
!
PIN seed. Optional. The base seed number used when generating PINs. The value entered
here has priority over the default PIN seed value entered on the [pndfentr] screen (see
Entering Default PIN Digits and Seed for an SE 422 in this section). Default is 0.
"
PIN Digits. The number of digits in the PIN code for this SE 422. The value entered here
has priority over the default PIN digits value entered on the [pndfentr] screen (see Entering
Default PIN Digits and Seed for an SE 422 in this section). Default is 0.
#
EMPI Alt2 Code. Optional. Alternate EMPI site code #2.
$
# of Retry Times. Used to inform a remotely connected SE 422 the number of times to
attempt to contact the host computer over telephone lines before considering a connection
to be currently impossible to make.
%
XON/XOFF. Terminal Port and Host Port: Used to inform the SE 422 whether XON/XOFF
flow control will be used at either of these two ports. Used for remotely connected SE 422s
only.
&
Bldg Mode Indicators. Conditional. Enter the input point contact number or output relay
number to initiate and display the status of the building mode.
Monitor — Input point contact ID (0 — 75)
Open, Limited, Closed — Output point relay ID (0 — 51)