SP program
program:
Either an integer between
1
and
65,535
(representing a number) or an alphanumeric string
(representing a name), preference being on a number to resolve ambiguity.
Command changes selected
program
by Program Number (from PAT) or SDT descriptor. This command
works similarly to a
PERM command.
TEMP [format] [feed #] [carrier freq] [data rate] [FEC] [Tag Site] program# time
For
format, feed #, carrier freq, data rate, FEC, tag site, and program #, see
PERM
command.
time:
Length of insert in either
HH:MM:SS
format (valid range is
0:00:00
to
18:00:00
, leading zeros
OK to omit on hours) OR in number of seconds. (A one-hour
TEMP
could have a
parameters: of
1:00:00
or
3600
.)
Command which performs a volatile temporary insert for an amount of time given by
time. Unit sets its
temporary Unit Settings to the values given.
Note:No label may be applied using this terminal command.
TEMPCH value time
value:
Either the value of a Preset table entry number OR the Channel Label of an entry, priority
given to Label if any ambiguity. If an entry number, legal values range from
1
up to
N
(where
N
is number of Preset support this product).
time:
Same as for
TEMP
.
Volatile command which sets volatile temporary Unit Settings to those retrieved from the Preset table
according to
value for time given by time. Similar to TEMP command.
TEMPSENS
Command displays internal unit temperature if available.
TEST group value
group:
Mnemonic for a test group: Either
RF
,
AV
,
DTMF
, or
REL
.
value:
Parametric value which has meaning depending on the test group selected.
Command to activate Installation Test Modes. A Local Control Command (available from the terminal
regardless of "Local Control Enable/Disable" commands from the network).
If
group is
RF
, the legal
values are
1
,
2
,
3
,
4
, and
OFF
. Entering numbers for value cause the IRD to report
the RF level (not locked to carrier) at that RF Feed Port every few seconds. Entering
OFF
stops the
measurement.
If
group is
AV
, the legal
values are
ON
and
OFF
. If
ON
, a test pattern is activated on the video output and
test tones activated on the audio output, the same as the generic
TESTMODE
command.
If
group is
DTMF
, the legal
values are
ON
and
OFF.
If
ON
, the command behaves like the
DTMFVOL
command entered with no parameters
If
group is
REL
, the legal
values are
ON
and
OFF
. If
ON
, both user cue relays are alternately energized
and de-energized.
TESTOFF
Command stops all volatile test functions as if unit were reset. A Local Control Command (available from
the terminal regardless of "Local Control Enable/Disable" commands from the network).
Table 3.3: Command Directory for U4600 Terminal Commands