Wegener Communications UNITY 4600 User Manual
Page 46
U
NITY
4600 U
SER
’
S
M
ANUAL
800032-01 Rev. F
38
www.wegner.com
PARTPID pid
pid:
Hex value between
20
and
1FFE
to set a value, and
0
to disable.
Command sets the borderline (or “partition”) PID at, and above which, the IRD may expect compatible
scrambling against which it may apply the proper descrambler. PIDs below this point may be scrambled
with an alien, 3rd party system. See individual IRD specs for more detail on unit behavior. A Local Control
Command (available from the terminal regardless of "Local Control Enable/Disable" commands from the
network).
PC device baud parity
device:
One of
MODEM
,
TERMINAL
,
AUXDATA
,
CA
, or
COMPEL
.
baud:
1200
,
2400
,
4800
,
9600
,
19200
, or
38400
.
parity:
N
,
E
, or
O
.
Configures communication parameters for any serial device. A Local Control Command (available from
the terminal regardless of "Local Control Enable/Disable" commands from the network).
PERM [format] [pol/feed#] [carrier freq] [data rate] [FEC] [Tag Site] [program#] [label]
format:
If an
RF
input, one of the legal modulation formats:
QPSK
for
DVB-QPSK
;
8PSK
for
DVB-
8PSK
;
TQPSK
for
Turbo-QPSK
);
T8PSK
for
Turbo-8PSK
;
T16QAM
for
Turbo-16-QAM
; or
16QAM
for
DVB 16QAM
. May be omitted if
DVB-QPSK
.
For an
ASI Transport
input, specify
ASI
. If this parameter is set to
OK
, then the current
setting, if a Transient setting, becomes the new Permanent setting.
pol/feed#:
If an
RF
input, one of four possible RF feeds,
1
,
2
,
3
or
4
.
If an
ASI
input, one of two possible ASI feeds,
1
or
2
.
If no RF option, this field may be used for
ASTRA
polarization,
H
or
V
.
This field may be omitted if no RF switch option is installed.
carrier freq:
If an RF input, the downlink carrier frequency in MHz (precision to two decimal places
OK). Field is omitted for an ASI input only.
data rate:
If an RF input, the Transport data rate in Mbps (precision to two decimal places OK).
Field is omitted for an ASI input only.
FEC:
If an RF input, the inner FEC ratio. Field is omitted for an ASI input only.
The legal options are: for
QPSK
-
1/2
,
2/3
,
3/4
,
5/6
, and
7/8
;
for
8PSK
-
2/3
,
5/6
,
8/9
; and for
16 QAM
-
3/4
, and
7/8
.
Other legal values may be defined for new modulation formats.
tag site:
If an RF input, the tag site for Carrier ID tag. Field is omitted for an ASI input only.
program#:
Program number, ‘*’ for wildcard, or null (for no program assigned).
label:
Channel Label (optional, may be omitted).
Command to establish new Permanent Unit Setting with the parameter values given. If the format is set
to
OK
, no other parameters are accepted or required.
Table 3.3: Command Directory for U4600 Terminal Commands