Wegener Communications UNITY 4600 User Manual
Page 50
U
NITY
4600 U
SER
’
S
M
ANUAL
800032-01 Rev. F
42
www.wegner.com
RPATH TO username@addr
username:
Legal string of keyboard characters without white space.
addr:
IP address formatted as
n1:n2:n3:n4
where n
n1
,
n2
,
n3
, and
n4
are integers between
0
and
255
.
Email address destination for Return Path reporting. A Local Control Command (available from the
terminal regardless of "Local Control Enable/Disable" commands from the network).
SAVENV
Saves all the current global and Unit Setting NV parameters (in NVRAM) to the Flash memory space
designated as
BACKUP
.
Note: Some unit-set parameters, which would not make sense to “back up”, may not be saved.
A Local Control Command (available from the terminal regardless of "Local Control Enable/Disable"
commands from the network).
SAVEP [entry#] [channel_label]
entry#:
A Preset Table Entry number or the text,
PERM
. If a preset entry, must be equal to a
number between
1
and
N
inclusive, where
N
is the highest entry number.
channel_label: Channel Label associated with a unit setting or a Preset Table entry. If attempting to
supply the
channel_label
parameter alone, a value of
PERM
is not legal. Parameter must
be a string of continuous non-white-space keyboard characters. Unit will truncate user
input to 10 characters.
Command saves current Unit Settings to a Preset Table entry, or if
entry#
is
PERM
, a current Transient
Setting is loaded into the unit's Permanent unit setting. Those metadata fields in the extended Preset
Entry that have no analog in the current Unit setting will be populated with spec defaults. User must use
ADDE
command to set those fields.
If
entry# is supplied alone, current unit settings are written to that entry, overwriting existing data if it had
been in use. If
channel_label is supplied alone, and if that same Label already appears at a used Preset
Table entry, then the current unit settings overwrite that old Preset data. If
channel_label is supplied
alone and no used Preset has that Label, then the current settings are written to the lowest empty Preset
Table entry and then given that same Label. If both
entry# and channel_label parameters are supplied,
then the current unit settings are written at that Entry (overwriting existing data if any) and that entry is
supplied that same Label (equal to
channel_label).
SERVICE video_pid [pcr_pid] [audio1_pid] [audio2_pid]
video_pid:
Hex value between
20
and
1FFE
.
audio1_pid:
Hex value between
20
and
1FFE
.
audio2_pid:
Hex value between
20
and
1FFE
.
pcr_pid:
Hex value between
20
and
1FFE
.
Command selects A/V services directly by PID number only. This changes Unit Setting #11 to “By PID” if
not already set that way.
Table 3.3: Command Directory for U4600 Terminal Commands