beautypg.com

Wegener Communications UNITY 4600 User Manual

Page 37

background image

U

NITY

4600 U

SER

S

M

ANUAL

www.wegener.com

29

800032-01 Rev.F

On the

Home screen, the

(right-pointing arrow) field will quickly flash (a half-second ON

and a half-second OFF) to signal the user that the right arrow button is active for user con-
trol. Pressing either the left or right arrow buttons will cause the

U4600 to display the other

top-level screens in succession. If there are current alarm and warning indications, the text
"

See Alarms" or "See Warnings" will appear before the arrow and pressing the right arrow

will display the applicable alarm or warning message(s).

Interpreting
Front Panel
LEDs

Table 3.2: Front-Panel LED Indicator Descriptions provides the meaning of the color and
state of each LED in

Figure 3.5 below.

Figure 3.5: LED Indicators.

Table 3.2: Front-Panel LED Indicator Descriptions

Indicator Label

Color and State*

Meaning

CARRIER

GREEN constant

Unit has demod and FEC lock on the RF carrier

Off

Unit does not have demod and FEC lock on the RF carrier

TRANSPORT

GREEN constant

Unit recognizes a valid transport stream

Off

Unit does not recognize a valid transport stream

COMPEL

GREEN constant

COMPEL control stream received within last two minutes
(including keep-alives) while locked continuously on the current
transport stream for >2 minutes

GREEN flash

Unit has had a verified transport stream for >2 minutes and
COMPEL is required but no valid COMPEL

GREEN flutter

COMPEL has been addressed to unit within last 5 seconds
(excluding keep-alives)

Off Otherwise.

Note that this LED must be OFF when there is no valid Transport
stream OR COMPEL

SERVICES

GREEN constant

Unit is processing services for delivery

Off

Unit is not processing services

WARNING

YELLOW constant

One or more warning indications exist, usually the failure of a non-
essential item, or to warn of an impending failure of an essential
item

Off

No warning conditions