On the
Home screen, the
(right-pointing arrow) field will quickly flash (a half-second ON
and a half-second OFF) to signal the user that the right arrow button is active for user con-
trol. Pressing either the left or right arrow buttons will cause the
U4600 to display the other
top-level screens in succession. If there are current alarm and warning indications, the text
"
See Alarms" or "See Warnings" will appear before the arrow and pressing the right arrow
will display the applicable alarm or warning message(s).
Interpreting
Front Panel
LEDs
Table 3.2: Front-Panel LED Indicator Descriptions provides the meaning of the color and
state of each LED in
Figure 3.5 below.
Figure 3.5: LED Indicators.
Table 3.2: Front-Panel LED Indicator Descriptions
Indicator Label
Color and State*
Meaning
CARRIER
GREEN constant
Unit has demod and FEC lock on the RF carrier
Off
Unit does not have demod and FEC lock on the RF carrier
TRANSPORT
GREEN constant
Unit recognizes a valid transport stream
Off
Unit does not recognize a valid transport stream
COMPEL
GREEN constant
COMPEL control stream received within last two minutes
(including keep-alives) while locked continuously on the current
transport stream for >2 minutes
GREEN flash
Unit has had a verified transport stream for >2 minutes and
COMPEL is required but no valid COMPEL
GREEN flutter
COMPEL has been addressed to unit within last 5 seconds
(excluding keep-alives)
Off Otherwise.
Note that this LED must be OFF when there is no valid Transport
stream OR COMPEL
SERVICES
GREEN constant
Unit is processing services for delivery
Off
Unit is not processing services
WARNING
YELLOW constant
One or more warning indications exist, usually the failure of a non-
essential item, or to warn of an impending failure of an essential
item
Off
No warning conditions