Configure lnb options, Lnb setup screen, Table 3.3 – Wegener Communications IPUMP 562 User Manual
Page 28: Figure 3.5
Operation
18
800092-01 Rev. A
www.wegener.com
Figure 3.5: iPump 562 OSD Current Channel Screen
Use the
Current Channel
screen to set or display the channel information.
Table 3.3: Channel Information Options
Configure
LNB options
LNB Setup screen
Use following steps to display
LNB Setup
screen on the OSD menu:
1. Press any push-button on the front-panel to display the
Main Menu
.
2. Press the down arrow button to select
Carrier Settings
.
3. Press
Enter
.
4. Press the down arrow button to select
LNB Setup
.
5. Press
Enter
details the
LNB Setup
screen.
6. To navigate the screen, use down arrow and
Enter
to select an option. When the
corresponding value of that option on the left is selected, use up or down buttons to
set to the desired setting. Press
Enter
when done. Move to the next option using up
or down button or left arrow to exit to the previous menu level.
Option
Possible values
Comments
Preset
Perm, Command, Last
Success or Current
Only Perm option allows other options to be set.
The channel set using the
Compel Command.
Modulation
QPSK/S2QPSK/S28PSK
-
FEC Ratio
1/2, 2/3, ¾, 5/6, 7/8
-
Frequency
Data Rate
Symbol Rate
Automatically calculated and displayed only
Program
Set to the desired program # in the carrier
Tag Site
The tag #15 is a special value