VBrick Systems 7000 User Manual
Page 36

30
© 2009 VBrick Systems, Inc.
Table 3. Trap Summary
Authentication Password Enter password. Cannot exceed 20 characters. May include any
combination of alphanumeric characters but only the following 
special characters: 
~ ! # $ ^ * + & [ ] { } | < >
Authentication Protocol Select protocol: MD5 or SHA to validate the transaction
between a given host and client
Privacy Password
Required. Hides traffic using DES encryption.
Security Level
No Authentication, No Privacy (default).
No Privacy.
Authentication and Privacy.
Trap
Description
1
vbrickRemoteLog
Sent whenever a significant event occurs within 
the VBrick. Each event provides details via the 
vbrickSysRemoteEventLogType, and 
vbrickSysRemoteEventLogText objects
2
vbrickSysTrapStartUpRunMode
Means the VBrick has started up in Run mode.
3
vbrickSysTrapStartUpDiagnosticsMode
The VBrick has started in Diagnostics mode.
4
vbrickSysTrapStartUpLimitedRunMode
Means the VBrick has started up in LimitedRun 
mode.
5
vbrickSysTrapUserInitiatedReset
Means the VBrick has received a reset request 
from an administrator. 
6
vbrickSysTrapTemperatureOutOfRangeActive
Means the temperature of the VBrick is out of 
range.
7
vbrickSysTrapTemperatureOutOfRangeCleared
Means the out of range VBrick temperature is 
recovered.
8
vbrickSysTrapUnitOverloadedActive
Means the VBrick has been configured to 
transmit and receive video streams beyond its 
capability.
9
vbrickSysTrapUnitOverloadedCleared
Means the overloaded VBrick is recovered to 
normal.
10
vbrickSysTrapPostFailure
Means that Power On Self Test (POST) failed.
11
vbrickSysTrapNetworkTimeProtocolServerDown
Means there is loss of connection to the 
Network Time Protocol servers.
12
vbrickSysTrapNetworkTimeProtocolServerUp
Means there is a connection available now to the 
Network Time Protocol servers.
13
vbrickSysTrapVideo1InputAlarmActive
Means that input #1 has a loss of video.
14
vbrickSysTrapVideo1InputAlarmClear
Means the loss of video on input #1 is 
recovered.
15
vbrickSysTrapFanFailureActive
Means the fan failed.
16
vbrickSysTrapFanFailureCleared
Means the fan failure is recovered.