VBrick Systems 7000 User Manual
Page 32

26
© 2009 VBrick Systems, Inc.
Passthrough State: Responder
Passthrough State
Responder – In this case the VBrick will accept a connection request 
(up to 64 connection requests). 
Baud Rate
Rate of Passthrough port. Rate can be set to the following (Default 
= 9600): 110, 300, 600, 1200, 2400, 3600, 4800, 7200, 9600, 14400, 
19200, 28800, 38400, 57600, 115200.
Stop Bits
Number of stop bits for Passthrough port (1 or 2).
Parity
None, Even, Odd.
RTS Control
Force OFF, Force ON or Automatic. If automatic, the control will be 
on when Passthrough is active. Under no conditions are RTS or 
DTR controls passed through end-to-end. All control handling is 
local. When using a VBrick VCC-3 or VCC-4 camera, set this control 
to Automatic; when using a VBrick VCC-50i camera, set this control 
to Force ON.
DTR Control
Force OFF, Force ON or Automatic. If automatic, the control will be 
ON when Passthrough is active. Under no conditions are RTS or 
DTR controls passed through end-to-end. All control handling is 
local. When using a VBrick VCC-3 or VCC-4 camera, set this control 
to Automatic; when using a VBrick VCC-50i camera, set this control 
to Force ON.
COM Interface Type Describes the COM interface connector.
• RS232 – standard RS-232 serial port connector.
• RS422/485 – RS-422/485 4-wire serial port connector.