41
Start Remote Mode and Change Transfer Speed:
Through the Menu system, select
3:SYSTEM OPTION /
5:PC CONTROL by rotating the VFO and pressing E. To
start Remote mode, choose from the transfer speed list except
for
5:OFF.
A unique feature of the UBC785XLT is that all the front panel keys as well as the VFO on
the radio remain operational in Remote mode.
For information on purchasing cables, connectors, and optional ARC785 software to
program and control your UBC785XLT, please contact your distributor and /
or you can contact the following :
www.racescanner.eu
PC Control Parameter
For your information:
Transfer speed : 2400/4800/9600/19200 bps (adjustable)
Start/Stop
: 1 bit, 1 bit
Data Length
: 8 bit
Parity bit
: None
Code
: ASCII code
Flow Control
: None
Return Code
: Carriage Return only
Clone Mode
You will need to purchase a RS232C straight cable a null modem adapter. RS232C straight
cables are available as male to male or male to female. Even if the RS232C straight cable
you buy already has the male to male connectors, you will still have to have the null modem
adapter. On the next page you will see the pin connections that are internal to a standard
device. (These items are available at your local electronics stores.)
SPEED
3:9600 bps
4:19200 bps
5:OFF