Fault relay alarm, Sntp configuration – Transition Networks SISGM1040-244 User Manual
Page 75

Transition Networks
SISGM1040-244
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Fault Relay Alarm
Power Failure: Mark the check box to enable the function of lighting up FAULT LED
on the panel when power fails.
Port Link Down/Broken: Mark the check box to enable the function of lighting up
FAULT LED on the panel when Ports’ states are link down or broken.
Fault Relay Alarm interface
SNTP Configuration
You can configure the SNTP (Simple Network Time Protocol) settings. The SNTP allows
you to synchronize switch clocks in the Internet.
1. SNTP Client: enable or disable SNTP function to get the time from the SNTP server.
2. Daylight Saving Time: enable or disable daylight saving time function. When
daylight saving time is enabling, you need to configure the daylight saving time
period..
3. UTC Timezone: set the switch location time zone. The following table lists the
different location time zone for your reference.
Local Time Zone
Conversion from UTC
Time at 12:00 UTC
November Time Zone
- 1 hour
11am