beautypg.com

C-001t (control i/o expansion module), Zp-001t (zone paging module) – TOA Electronics M-9000 User Manual

Page 14

background image

14

7.2.4. ZP-001T (Zone paging module)

OUT

CONTACT

3

4

1

2

OUT

TEL IN

IN

ZP-001T

5

6
7

8

5. Telephone input terminal [TEL IN] (Modular jack)

Interface connector for an analog PABX.
Connect a PABX to this terminal when using the module in the ring
signal mode.

6. Telephone input terminal [TEL IN]

4-pin removable terminal block, 2 pins are used for this input.
This terminal is internally connected in parallel with the telephone input
terminal (modular jack) (5).
Connect a PABX to this terminal when the paging trunk is used (paging
trunk mode).

7. Contact input terminal [CONTACT IN]

4-pin removable terminal block, 2 pins are used for this input.
Connect the contact output from a PABX to this terminal.

8. Contact output terminals [OUT 1, 2, 3, 4]

4-pin removable terminal blocks, contact output terminals.
This terminal is not used with the current firmware. It will be made usable
in the near future when the firmware version is upgraded.
For details, please contact your nearest TOA dealer.

7.2.3. C-001T (Control I/O expansion module)

OUT

IN

1
2
3
4
5
6
7
8
E

C-001T

3

4

3. Contact input terminal [IN 1, 2, 3, 4, 5, 6, 7, 8, E]

9-pin removable terminal block, 8-circuit contact input terminal.
Individual contact functions are assigned on the front panel setting
screen of the main unit.

4. Contact output terminal [OUT 1, 2, 3, 4, 5, 6, 7, 8, E]

9-pin removable terminal block, 8-circuit contact output terminal.
Individual contact functions are assigned on the front panel setting
screen of the main unit.

The C-001T module is designed for use with the 9000 Series amplifiers and can provide up to 8 channels
each of input and output expansion.
Since the main unit has 4 fixed inputs and outputs each, the control input and output can be expanded to up to
12 channels each when the C-001T module is used.

The ZP-001T is designed for use with the 9000 Series amplifiers and functions as an interface to connect the
9000 Series amplifiers to an analog PABX, allowing zone paging to be initiated from the PABX.

There are two operation modes: ring signal and paging trunk modes. Select one of the two modes when using
this module.