Administrator Settings
153
Signal levels -
line level inputs
Clipping level
Nominal
level
Input menu level
settings
Vpp
dBu
dBu
0.0 dB
15.5 Vpp
17.0 dBu
-1.0 dBu
1.5 dB
13.0 Vpp
15.5 dBu
-2.5 dBu
3.0 dB
11.0 Vpp
14.0 dBu
-4.0 dBu
4.5 dB
9.2 Vpp
12.5 dBu
-5.5 dBu
6.0 dB
7.8 Vpp
11.0 dBu
-7.0 dBu
7.5 dB
6.5 Vpp
9.5 dBu
-8.5 dBu
9.0 dB
5.5 Vpp
8.0 dBu
-10.0 dBu
10.5 dB
4.6 Vpp
6.5 dBu
-11.5 dBu
12.0 dB
3.9 Vpp
5.0 dBu
-13.0 dBu
13.5 dB
3.3 Vpp
3.5 dBu
-14.5 dBu
15.0 dB
2.8 Vpp
2.0 dBu
-16.0 dBu
16.5 dB
2.3 Vpp
0.5 dBu
-17.5 dBu
18.0 dB
2.0 Vpp
-1.0 dBu
-19.0 dBu
19.5 dB
1.6 Vpp
-2.5 dBu
-20.5 dBu
21.0 dB
1.4 Vpp
-4.0 dBu
-22.0 dBu
22.5 dB
1.2 Vpp
-5.5 dBu
-23.5 dBu
Table2: Signal Levels - Line level inputs
Note that for the dBu value for input clipping level and absolute max output level, a sine waveform
is assumed. If numbers in dBV are required, dBV value is 2.2 dB lower than the dBu value, e.q. -
10 dBu equals -12.2 dBV
Please see
Interfaces
for details on the audio connectors.