Rwd/rws gen 2 relay board pin-out descriptions – TurboChef Technologies Residential Single and Double Wall Oven User Manual
Page 89
OVEN
SCHEM
A
TICS
7.7
1
1
5
4
1
25
1
3
1
8
2
2 6
1
11
Lower Door Light
Convection Fan
Lower Cooling Fan
Lower Door Lock
Upper Door Light
Stirrer Motor
Upper Cooling Fan
M
ag F
a
n
P
re
-Heat
e
r
1
Door Lock
15 AMP
20 AMP
HV
Transformer
HV
Transformer
Monitor
12VAC
Transformer
Upper Right
Door Lock
Upper Left
RWD/RWS GEN 2 RELAY BOARD
Pin-out descriptions
REV. B 9_08
Enable Inputs from I/O board
J21-1 HX1 Heater
J21-2 HX2 Heater
J21-3 Convection Heater
J21-4 Bake Heater
J21-5 Broil Outer Heater
J21-6 Broil Inner Heater
J21-7 Pre heat Heater
J21-8 Blower Upper
J21-9 Blower Lower
J21-10 PWM0
J21-11 PWM1
J21-12 Door Latch 1
J21-13 Door Latch 2
J21-14 Door Latch Lower
J21-15 Convection Fan
J21-16 Mag 1
J21-17 Mag 2
J21-18 Mag Fan
J21-19 Stirrer Motor
J21-20 Door Light
J21-21 Door Light Lower
J21-22 Cooling Fan
J21-23 Cooling Fan Lower
J21-24 Spare
J21-25 Spare
J21-26 Monitor Interlock
J22-1 HX1 Heater output
J22-2 HX2 Heater output
J22-3 Upper Blower enable
J22-4 Lower Blower enable
J22-5 PWM0 0-10VDC upper
J22-6 PWM1 0-10VDC lower
J22-7 +24V (output)
J22-8 Ground
J22-9 Cooling Fan CTL
J22-10 Ground
J22-11 Door Light output
J17-1 Convection Heater (output)
J17-2 Bake Heater (output)
J17-3 Broil Outer Heater (output)
J17-4 Broil Inner Heater (output)
J17-5 +24V (output)
J17-6 Cooling Fan CTL (input from
thermostats)
J20-3
Lower Cooling Fan (HV output)
J20-2 Convection Fan (HV output)
J20-1 Lower Door Lock (HV output)
J15-1 +24V (from PS)
J15-2 +24V (from PS)
J15-3 Ground (from PS)
J15-4 Ground (from PS)
J18-1 12.6VAC (output to clock)
J18-2 Common (output to clock)
J19-1 Mag Fan (HV output)
J19-2 Door Lock Up R (HV output)
J19-3 Door Lock Up L (HV output)
J19-4 Stirrer Motor (HV output)
J19-5 Cooling Fan Up (HV output)
J1
L1 Power (input to Mags RLY 2+3 thru F1)
J2
L2 Power (input to Monitor RLY 1)
J3
L2A Power (input to F2 fuse)
J4
T1-1 Power (L1 output to HV transformer)
J5
T2-2 Power (L1 output to HV transformer)
J6
L2-B Power (output from F2 fuse)
J7
L2 Power (input for Mag fan, Door locks 1+2,
Upper cooling fan, Stirrer motor)
J9
L2 Power (input for Lower door lock, Lower
cooling fan, and Convection motor)
J10
L1 Power input (from High Limit for Preheat)
J11
L1 Power output to Preheat Heater