Using the Menus

1740A/1750A Series Waveform/Vector Monitor User Manual

3-24

Gain Menu

H Any one of three calibrated gain ratios can be selected:

X1

,

X5

, or

X10

. Variable gain is also available, indepen-

dent of the other gain settings. When variable gain is on,
the left bezel control adjusts the signal gain.

H Audio or Time Code gain is set from the

GAIN

menu

when

AUDIO

or

TIME CODE

display is selected. Gain

choices are 0 dBu, 4 dBu, 8 dBu, or 12 dBu. Select gain
relative to the system under test.

H When variable gain is turned off, the instrument returns

to the calibrated gain setting. Operator adjustments
made with variable gain will be restored when variable
gain is selected again.

CRT Menu

H

DISPLAY

is used for signal and etched graticule adjust-

ments. When

DISPLAY

is selected, the left bezel control

adjusts the signal focus (

FOCUS),

the center bezel

control adjusts the etched graticule illumination

(SCALE)

and the right bezel control adjusts the signal intensity
(

INTENSITY).

H

READOUT

refers to electronic graticules, markers, menu

and measurement readouts. When

READOUT

is selected,

a test pattern containing a vertical line and a horizontal
line is displayed. Use the left bezel control

(VPOS)

and

the center bezel control

(HPOS)

until the lines cross at

the center of the etched graticule. This will compensate
for minor shifting of markers due to drift or external
magnetic fields (particularly if the instrument is moved
after the markers are set).

The right bezel control adjusts readout intensity

(INTEN-

SITY).

Readout intensity will not go below the calibrated

minimum value when menus are displayed.

H

TRACE

adjusts trace rotation

Exiting the menu will return the instrument to normal opera-