Tektronix 1740A/1750A User Manual
Page 51
Operator’s Checkout Procedure
1740A/1750A Series Waveform/Vector Monitor User Manual
2-21
LINE SEL
ALL131
FIELD
ALL 1OF2
1OF8
1OF4
1H
15H
-- -- 145
Figure 2-13. Line Select display with 15H selected, in 2 FIELD sweep.
Select
1 of2.
Now only the first field has intensified lines,
and a
NEXT FIELD
selection appears. Select
NEXT FIELD
and
note that the intensified lines now appear only in the second
field and the readout is
F2 131 F2 145.
Select
MULTIPLE
with
WAVEFORM, VECTOR,
and
SCH
(1750A--
Series only). Note that the displays appear in the order listed
here. Exit the line select menu. Enter the menu again and
note that the user settings are saved. Exit the menu.
10. Vectorscope Display
Select
VECTOR
display mode. Adjust the right bezel control
to place the burst vector on the 180
° graticule line. The
display should appear similar to Figure 2-14.
11. Picture Monitor Display
Select
PICTURE
display mode. A picture monitor display of
the selected input signal appears. This can be used to visual-
ly identify the signal source. See Figure 2-15.