At A Glance

1740A/1750A Series Waveform/Vector Monitor User Manual

2-6

REF

H

EXT

toggles between external reference

(

EXT

LED

on) and internal reference. Internal reference can be
configured for component operation, and two
external reference inputs can be designated for
dual-standard instruments. See the

CONFIGURE

men

on page 3-18.

INPUT

H Selecting a front-panel input causes the signal that is

input to the corresponding rear-panel connector to
be displayed on screen.

H Without

PARADE

or

OVERLAY

selected, only one

input selection can be made at a time. Each input
channel button (including

A123 / B123

) toggles

between

A

and

B

,

and is cancelled when another

input button is pressed.

H With

PARADE

or

OVERLAY

selected, multiple input

selections can be made; input buttons select

A, B

,

both, or off, and do not cancel each other.

A123

A123

provides a side-by-side display of the

CH-A1

,

CH-A2

,

and

CH-A3

inputs (

B123

displays the

CH-B1

,

CH-B2

,

and

CH-B3

inputs). Selecting

A123

or

B123

turns off all other input channels. When

PARADE

or

OVERLAY

is selected,

A123

and

B123

can be displayed

together and in combination with other inputs.

PARADE

PARADE

displays up to four input channels side-by-

side, with any additional inputs overlaid. Selecting

PARADE

displays the input channel(s) last selected

for

PARADE,

allowing a custom configuration of

inputs. In

PARADE

mode, the

LINE/FIELD

button

offers only two choices: one line and one field.