beautypg.com

Specifications, 1 models and their standard specifications, Qstandard specifications – Toshiba VF-S11 User Manual

Page 71

background image

E6581160

70

8

8. Specifications

8.1

Models and their standard specifications

Q

Standard specifications

Item

Specification

Input voltage

3-phase 240V

Applicable motor (kW)

0.2

0.4

0.55

0.75

1.5

2.2

4.0

5.5

7.5

11

15

Type

VFS11

Form

2002PM 2004PM 2005PM 2007PM 2015PM 2022PM 2037PM 2055PM 2075PM 2110PM 2150PM

Capacity (kVA) Note 1)

0.6

1.3

1.4

1.8

3.0

4.2

6.7

10

13

21

25

Rated output/current

(A) Note 2)

1.5

(1.5)

3.3

(3.3)

3.7

(3.3)

4.8

(4.4)

8.0

(7.9)

11.0

(10.0)

17.5

(16.4)

27.5

(25.0)

33

(33)

54

(49)

66

(60)

Output voltage Note 3)

3-phase 200V to 240V

Rat

ing

Overload current rating

150%-60 seconds, 200%-0.5 second

Voltage-frequency

3-phase 200V to 240V - 50/60Hz

Po

w

er

supp

ly

Allowable fluctuation

Voltage + 10%, -15% Note 4), frequency ±5%

Protective method

IP20 Enclosed type (JEM1030)

Cooling method

Self-cooling

Forced air-cooled

Color

Munsel 5Y-8/0.5

Built-in filter

Basic filter

Item

Specification

Input voltage

1-phase 240V

3-phase 500V

Applicable motor (kW)

0.2

0.4

0.75

1.5

2.2

0.4

0.75

1.5

2.2

4.0

5.5

7.5

11

15

Type

VFS11S

VFS11

Form

2002PL 2004PL 2007PL 2015PL 2022PL 4004PL 4007PL 4015PL 4022PL 4037PL 4055PL 4075PL 4110PL 4150PL

Capacity (kVA) Note 1)

0.6

1.3

1.8

3.0

4.2

1.1

1.8

3.1

4.2

7.2

11

13

21

25

Rated output current

(A) Note 2)

1.5

(1.5)

3.3

(3.3)

4.8

(4.4)

8.0

(7.9)

11.0

(10.0)

1.5

(1.5)

2.3

(2.1)

4.1

(3.7)

5.5

(5.0)

9.5

(8.6)

14.3

(13.0)

17.0

(17.0)

27.7

(25.0)

33

30)

Rated output voltage Note 3)

3-phase 200V to 240V

3-phase 380V to 500V

Rat

ing

Overload current rating

150%-60 seconds, 200%-0.5 second

150%-60 seconds, 200% -0.5 second

Voltage-current

1-phase 200V to 240V – 50/60Hz

3-phase 380V to 500V - 50/60Hz

Po

w

er

supp

ly

Allowable fluctuation

Voltage + 10%、-15% Note 4),

frequency±5%

Voltage + 10%, -15% Note 4), frequency ±5%

Protective method,

IP20 Enclosed type (JEM1030)

IP20 Enclosed type (JEM1030)

Cooling method

Self-cooling

Forced air-

cooled

Forced air-cooled

Color

Munsel 5Y-8/0.5

Munsel 5Y-8/0.5

Built-in filter

EMI filter

EMI filter

Item

Specification

Input voltage

3-phase 600V

Applicable motor (kW)

0.75

1.5

2.2

4.0

5.5

7.5

11

15

Type

VFS11-

Form

6007P

6015P

6022P

6037P

6055P

6075P

6110P

6150P

Capacity (kVA) Note 1)

1.7

2.7

3.9

6.1

9

11

17

22

Rated output/current

(A) Note 2)

1.7

(1.5)

2.7

(2.4)

3.9

(3.5)

6.1

(5.5)

9.0

(8.1)

11.0

(9.9)

17.0

(15.3)

22.0

(19.8)

Output voltage Note 3)

3-phase 525V to 600V

Rat

ing

Overload current rating

150%-60 seconds, 200%-0.5 second

Voltage-frequency

3-phase 525V to 600V - 50/60Hz

Po

w

er

supp

ly

Allowable fluctuation

Voltage + 10%, -15% Note 4), frequency ±5%

Protective method

IP20 Enclosed type (JEM1030)

Cooling method

Forced air-cooled

Color

Munsel 5Y-8/0.5

Built-in filter

No filter