Frequency parameters – Toshiba VF-S11 User Manual
Page 55
E6581160
54
7
Title
Communication
No.
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
E6581158
0: H and H
H
and H
1: H or H
H
and H
2: H and H
H
or H
H
0139
Output terminal
logic selection
(RY-RC, OUT-
NO)
-
-
3: H or H
H
or H
0
6.3.4
H
0167
Frequency
command
agreement
detection range
Hz
0.1/0.01
0.0-HJ
2.5
6.3.5
H
0170
Base frequency 2
Hz
0.1/0.01
25.0-500.0
50.0 (WP)
60.0
(WN, AN)
H
0171
Base frequency
voltage 2
V
1/0.1
50-330 (240V class)
50-660 (500/600V class)
* 3
H
0172
Torque boost
value 2
%
0.1/0.1
0.0-30.0
* 1
6.4.1
H
0173
Motor electronic-
thermal protection
level 2
%
(A)
1/1
10-100
100
5.13
6.4.1
H
0185
Stall prevention
level 2
%
(A)
1/1
10-199,
200 (disabled)
150
6.4.1
6.19.2
*1 : Default values vary depending on the capacity. See the table of page 64.
*3 : 230 (240V class), 460 (500V class), 575 (600V class)
• Frequency parameters
Title
Communication
No.
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
E6581158
0: HOQF (Switchable to H by
terminal input)
H
0200
Frequency priority
selection
-
-
1: HOQF (Switchable to H at
less than 1.0Hz of designated
frequency)
0
6.5.1
7.1
H
0201
VIA input point 1
setting
%
1/1
0-100
0
H
0202
VIA input point 1
frequency
Hz
0.1/0.01
0.0-500.0
0.0
H
0203
VIA input point 2
setting
%
1/1
0-100
100
H
0204
VIA input point 2
frequency
Hz
0.1/0.01
0.0-500.0
50.0 (WP)
60.0
(WN, AN)
6.5.2
H
0207
Frequency setting
mode
selection 2
-
-
0: Built-in potentiometer
1: VIA
2: VIB
3: Operation panel
4: Serial communication
5: UP/DOWN from external contact
6: VIA + VIB (Override)
1
6.3.5
6.5.1
7.1