Title
Communication
No.
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
E6581158
0: Supply voltage uncorrected, output
voltage limited
1: Supply voltage corrected, output
voltage limited
2: Supply voltage uncorrected, output
voltage unlimited
H
0307
Supply voltage
correction
(limitation of
output voltage)
-
-
3: Supply voltage corrected, output
voltage unlimited
2
(WP, WN)
3 (AN)
6.13.6
H
0308
Dynamic braking
resistance
Ω
0.1/0.1
1.0-1000
* 1
6.13.4
H
0309
Dynamic braking
resistor capacity
kW
0.01/0.01
0.01-30.00
* 1
6.13.4
H
0311
Reverse-run
prohibition
-
-
0: Forward/reverse run permitted
1: Reverse run prohibited
2: Forward run prohibited
0
6.13.7
H
0312
Random mode
-
-
0: Disabled
1: Automatic setting
0
6.12
0: Carrier frequency not reduced
automatically
1: Carrier frequency reduced
automatically
2: Carrier frequency not reduced
automatically
Support for 500V/600V models
H
0316
Carrier frequency
control mode
selection
-
-
3: Carrier frequency reduced
automatically
Support for 500V/600V models
1
6.12
H
0320
Droop gain
%
1/1
0-100
0
6.14
H
0323
Droop insensitive
torque band
%
1/1
0-100
10
6.14
H
0342
Braking mode
selection
-
-
0: Disabled
1: Enabled (forward run)
2: Enabled (reverse run)
3: Enabled (operating direction)
0
6.15
H
0343
Release
frequency
Hz
0.1/0.01
H
-20.0
3.0
H
0344
Release time
s
0.01/0.01
0.00-2.50
0.05
H
0345
Creeping
frequency
Hz
0.1/0.01
H
-20.0
3.0
H
0346
Creeping time
s
0.01/0.01
0.00-2.50
0.10
H
0359
PID control
waiting time
s
1/1
0-2400
0
6.16
H
0360
PID control
-
-
0: Disabled, 1: Enabled
0
H
0362
Proportional gain
-
0.01/0.01
0.01-100.0
0.30
H
0363
Integral gain
-
0.01/0.01
0.01-100.0
0.20
H
0366
Differential gain
-
0.01/0.01
0.00-2.5
0.00
*1 : Default values vary depending on the capacity. See the table of 64.