Acceleration/deceleration time parameters, Protection parameters – Toshiba VF-S11 User Manual
Page 60

E6581160
59
7
• Acceleration/deceleration time parameters
Title
Communication
No.
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
E6581158
H
0500
Acceleration time
2
s
0.1/0.1
0.0-3200
10.0
H
0501
Deceleration time
2
s
0.1/0.1
0.0-3200
10.0
H
0502
Acceleration/decel
eration 1 pattern
-
-
0
H
0503
Acceleration/decel
eration 2 pattern
-
-
0: Linear
1: S-pattern 1
2: S-pattern 2
0
H
0504
Acceleration/decel
eration selection
(1, 2 , 3)
-
-
1: Acceleration/deceleration 1
2: Acceleration/deceleration 2
3: Acceleration/deceleration 3
1
H
0505
Acceleration/decel
eration 1 and 2
switching
frequency
Hz
0.1/0.01
0.0-WN
0.0
H
0506
S-pattern lower-
limit adjustment
amount
%
1/1
0-50
10
6.18
H
0507
S-pattern upper-
limit adjustment
amount
%
1/1
0-50
10
H
0510
Acceleration time
3
s
0.1/0.1
0.0-3200
10.0
H
0511
Deceleration time
3
s
0.1/0.1
0.0-3200
10.0
H
0512
Acceleration/decel
eration 3 pattern
-
-
0: Linear
1: S-pattern 1
2: S-pattern 2
0
H
0513
Acceleration/decel
eration 2 and 3
switching
frequency
Hz
0.1/0.01
0.0-WN
0.0
6.18
• Protection parameters
Title
Communication
No.
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
E6581158
H
0601
Stall prevention
level 1
%
(A)
1/1
10-199,
200 (disabled)
150
6.19.2
H
0602
Inverter trip
retention selection
-
-
0: Canceled with the power off
1: Still retained with the power off
0
6.19.3
H
0603
Emergency stop
selection
-
-
0: Coast stop
1: Slowdown stop
2: Emergency DC braking
0
6.19.4
H
0604
Emergency DC
braking time
s
0.1/0.1
0.0-20.0
1.0
6.19.4
H
0605
Output phase
failure detection
mode selection
-
-
0: Disabled
1: At start-up (only one time after
power is turned on)
2: At start-up (each time)
3: During operation
4: At start-up + during operation
5: Detection of cutoff on output side
0
6.19.5
H
0607
Motor 150%-
overload time limit
s
1/1
10-2400
300
6.19.1
H
0608
Input phase failure
detection mode
selection
-
-
0: Disabled, 1: Enabled
1
6.19.6