beautypg.com

Inst alla tion manu al – Toshiba RAV-SM1100UT-E User Manual

Page 75

background image

72

INST

ALLA

TION MANU

AL

85464359426000 (EN)

T

o

P

e

rsonnel Char

g

ed in Installation

W

ork and Ser

vice

Remote Contr

oller

Wireless Kit

MODEL :

TCB-AX21U (W)-E

Ho

w to install the sensor

s

*

The positions where the sensors can be installed are limited to the

cor

ners (

A

) in Fig.

1.

Theref

ore

, f

or installation of the sensor units

,

consider the direction when a panel is installed to the indoor unit.

1.

Remo

v

e

the suction gr

ille.

2.

T

a

k

e

off the scre

w fixing the cor

ner cap and remo

v

e

the cor

ner cap

sliding it side-w

ard.

(Fig.

2)

Fig. 1

Fig. 2

3.

The ther

mal insulation mater

ial is stuff

ed in the square hole

pro

vided to pass through cab

les of the panel, so tak

e off it once

and pass the cab

le out of the sensor of wireless remote controller

through the gr

ille

. Using a clamp

, fix the cab

le with scre

ws and

then be sure to stuff again the remo

v

ed ther

mal insulation mater

ial

as or

iginal.

(Fig.

3)

If the ther

mal insulation mater

ial is not stuff

ed, de

wing ma

y

happen.

Fig. 3

4.

After cab

ling according to

“Ho

w to perf

o

rm cab

ling of sensor units

”,

remain the cab

le length enough to remo

v

e

the sensor unit and fix it

with scre

ws using a clamp

. (Fig.

3)

5.

Install the sensor units to the panel.

In this time

, slide the panel so

that the hooks are fit in completely at 3 positions.

And also be careful not to pinch the cab

le.

(Fig.

4)

Fig. 4

NO

TES :

1.

A

v

oid to twist the cab

les of the operation section with cab

les of the

p

o

w

er supply

, etc.

It causes a malfunction.

2.

When noise is contained to the po

wer supply of the indoor unit,

counter measures such as mounting the noise filter is necessar

y.

Ho

w to perf

orm cab

ling of sensor units

Connection dia

gram

T

o

operate a gr

oup contr

ol of m

ultiple indoor units by 2 remote

contr

oller

s

*

Master and Sub remote controllers are oper

a

b

le e

v

en if the

y are

installed to an

y indoor unit.

(T

otal cab

le length:

Within 200m)

Ho

w to set the r

oom temperature

sensor

The room temperature sensors are equipped in the indoor unit and

the wireless remote controller

. One of two sensors w

o

rk

s

.

The room temper

ature sensor is set to the indoor unit side at the

shipment from the f

actor

y.

T

o

select the sensor in the remote

controller

, push the SENSOR b

utton (Right figure) inside of the

remote controller co

v

er and chec

k

Main sensor

” disappears from

LCD

.

Ho

w to set the ad

dress s

witc

h

When the m

ultiple sensors are installed in the same room, an

address can be set to pre

v

ent cross comm

unication.

When replacing the batter

y and pushing SET b

utton, the address of

the remote controller becomes [ALL] and the sensor is enab

led to

receiv

e signal regardless of setting of address s

witch of the

oper

ation section.

F

or selecting of the remote controller address

, ref

er to Owner

’s

Man

ual.

Change the address of the sensor b

y

remo

ving scre

ws of P

.C

. board

co

v

er of the sensor unit.

After then, fix the co

v

er with screws using

a clamp

.

Slide s

witc

h

Chec

k the slide s

witch in the batter

y bo

x of the remote controller is

set to [S] / [A] at shipment from the f

actor

y.

Do not change the setting.

T

est run

Ho

w to use [TEST]

1.

T

u

rn

No

.1 of DIP s

witch [S003] on sensor P

.C

. board from OFF to

ON.

2.

Dur

ing the test r

un, all the indication lamps on LCD flash.

3.

Dur

ing the test r

un, the temper

ature cannot be controlled.

4.

After the test r

un, be

sure to tur

n DIP s

witch 1

from ON to OFF and

chec

k the indication

lamps do not flash.

Use [TEST] function

only f

or a test r

un,

otherwise the unit is

ov

e

rloaded.

Fix the

co

v

er as or

iginal.

Ho

w to

handle

the

remote

contr

oller

In case using remote contr

oller mounting to the wall,

etc.

Chec

k a signal is receiv

ed correctly b

y

pushing

b

utton

at

the

position to be fix

ed.

Cautions f

or installation of the remote contr

oller

T

o

operate the remote controller b

y

fixing it to the wall, etc.

with a

remote controller holder

, tur

n on the fluorescent lamp

, oper

ate the

remote controller at the position to be fix

ed, chec

k the air condi-

tioner nor

mally oper

ates

, and then mount it.

When the room temperature is sensed b

y

the remote controller

,

mount the remote controller pa

ying attention to the f

ollo

wing items

.

Place not e

xposed directly to cold or hot wind.

Place not e

xposed directly to the sunlight.

Other places where the remote controller is not influenced.

Explanation to customer

s

Hand ov

er the

“Owner

’s Manual

” and

“Installation Manuals

” to the

customer after installation wo

rk

s

.

Explain usage and maintenance of the remote controller according

to

“Owner

’s Manual

”.

Lamp indication

No indication e

ven if

the remote controller

is oper

ated.

Cause

P

o

w

er supply is not

tur

ned on.

Miscab

ling betw

een

sensor unit and indoor

unit

Def

ectiv

e connection

betw

een sensor unit

and indoor unit

Miscab

ling or def

ectiv

e

connection between

indoor and outdoor

units

Protectiv

e de

vice of

outdoor unit w

o

rk

s

.

Protectiv

e de

vice of

indoor unit w

o

rk

s

.

Measures

Che

c

k

cab

le

connection

and correct it.

Chec

k

outdoor unit.

Chec

k

indoor unit.

Self-dia

gnosis tab

le and measures

Lamp indication

of sensor

:

Goes off

:

Flash

(0.5-sec.

inter

v

a

l)

Drain pipe side

of indoor unit

Refr

igerant pipe

side of indoor unit

Sensor unit

installing position

A

(Right side of electr

ic

par

ts bo

x)

Electr

ic par

ts bo

x

of indoor unit

Scre

w

Cor

ner cap

Cor

ner cap

Ceiling panel

Slid

Remo

v

e

the ther

mal insulation

mater

ial, fix the cab

le with scre

ws

using a clamp

, and put in the

ther

mal insulation mater

ial again.

Connection

Connect the cab

les out of the sensor unit to the ter

minal b

loc

k f

o

r

remote controller cab

ling of the indoor unit.

(There is no polar

ity

.)

CN001

2P White

Indoor unit

Sensor unit P

.C

. board

T

e

rminal b

loc

k f

or

remote controller

cab

ling

White

Blac

k

Ea

rt

h

Wireless

remote controller kit

(Master)

CN1

Wired

remote controller

(Sub)

2

1

(Sold separately)

(Sold separately)

T

e

rminal b

loc

k f

or

remote controller cab

le

Remote controller cab

le

(Procured locally)

(0.5 to 2mm

²)

Indoor unit

2

1

Sensor

unit

Ear

th

Ear

th

Ear

th

(Sold separately)

(Sold separately)

T

e

rminal b

loc

k

for remote controller cab

le

Remote controller inter-unit cab

le f

or group control

(Procured locally) (0.5 to 2mm

²)

2

1

Wired

remote controller

(Sub)

Wireless

remote controller kit

(Master)

CN1

2

1

In

do

or

u

n

it

No

.1

In

do

or

u

n

it

No

.2

In

do

or

u

n

it

No

.3

Ear

th

In

do

or

u

n

it

No

.N

Sensor unit

NO

TE :

If the room temper

ature data from the

remote controller is not tr

ansmitted to

the unit f

or 10 minutes or more

, the

sensor at indoor unit side is automati-

cally selected e

v

en if the sensor at the

remote controller side is selected.

Fix the remote controller to

ward the

unit as possib

le

.

S001

4

6

S002

3 6

2 5

1 4

Address

select

Address

S002

3 6

2 5

1 4

Address

S002

3 6

2 5

1 4

Address

S001

4

6

Address

select

S001

4

6

Address

select

Displa

y of

remote

controller

address

Address

s

witch

position of

sensor

*

Address s

witch

of sensor unit

can be set any

position.

Address

Address

Address

Address

1

31

31

3

SK

N

AH

C

Select of operation mode

Set to A.

Select of flap indication

Set to S

.

AH

C

SK

N

Flashes alter

nativ

ely

Flashes alter

nativ

ely

1

2

3

4

ON

Sensor

P

.C

. board

Cor

ner cap

Co

v

e

r

S 003

Bit 1 :

OFF to ON

1

2

Mounting scre

w

T

russ tapping

4 x 16

T

o

tak

e off remote controller

,

pull it tow

ard y

ou.

Put on.

Push.

RESET b

utton

Co

v

e

r

Replacement of batter

y

1.

Holding the both ends of the cov

er and remo

v

e

it b

y

sliding

do

wnw

ard.

2.

Correctly inser

t 2 AAA alkali batter

ies matching + and - polar

ities

with indications.

3.

Push SET b

utton with something tipped and attach the co

v

e

r.

Accessor

y par

ts

Requirement

The control b

y

tw

o remote controllers is enab

led b

y

installing the

wireless remote controller with the wired remote controller f

or an

indoor unit.

(Max.

2 remote controllers of wireless or wired are installab

le

.)

“2-remote controllers

” controlling

means that one or m

ultiple units

are oper

ated b

y

the m

ultiple remote controllers.

NO

TES :

1.

Upon confir

mation of the ter

minal numbers of the indoor unit,

connect the remote controller cab

les without miscab

ling.

(If applied A

C

220/230/240

V

olt, damage the unit.)

2.

The multiple wireless remote controller kits cannot concurrently be

used f

or an indoor unit.

3.

When installing simultaneously the wireless remote controller with

the wired remote controller

, set one of them as the sub remote

controller

.

When setting the wired remote controller as the sub

, e

xchange the

address connector at the rear of P

.C

. board of wired remote

controller from master to sub remote controller

.

When setting the wireless remote controller as the sub

,

tur

n No

.3 of

DIP s

witch [S003] on P

.C

. board of wireless remote controller

sensor unit from OFF to ON.

T

o

operate an indoor unit b

y

2 remote contr

oller

s

*

The indoor unit is oper

ated if either wireless or wired remote

controller is set as master or sub remote controller

.

(T

otal cab

le length:

Within 400m)

P

a

rt

Name

Sensor unit

Remote controller

Remote controller

holder

Q

’ty

1

1

1

P

a

rt

Name

Batter

y

Owner

’s Man

ual

T

apping scre

w

M4 x 16mm

Clamper

Fixing scre

w

M4 x 12mm

Q

’ty

2

1

2

1

1

Ho

w to set the fan motor speed ref

er

to

the

O

WNER

’S MANU

AL

This manual is related to the following products: