Accessories – Toshiba RAV-SM1100UT-E User Manual
Page 53
50
•
The signal receiving par
t is mounted to the ceiling panel.
Signal Receiving P
a
rt
1
Emer
g
ency operation b
utton
2
Signal receiving par
t
The signal sent from the remote control-
ler is receiv
ed.
3
Displa
y lamp
One of displa
ys flashed while a troub
le
occurs
. When
the
displa
y
lamp
flashes,
ref
er to
“Bef
ore asking of repair
”.
4
lamp
This lamp goes on dur
ing oper
ation.
5
lamp
This lamp goes on while the timer is
reser
v
ed.
6
lamp
•
In heating oper
ation this lamp in the
follo
wing cases;
The operation has star
ted.
The temp
. controller has wor
k
ed.
The unit is under defrost oper
ation.
•
This lamp flashes while a troub
le
occurs
.
7
(S003-1)
T
rial
ON switch
This s
witch is not used in nor
mal time
, b
u
t
used in tr
ial operation time
.
8
(S003-3)
Priority/Secondar
y switc
h
Use this s
witch at the position of
[
(PRIORITY)
]
. This
s
witch
can
be
used
together with the wired remote controller
.
9
F
an speed c
hang
e tap 1 (S003-2)
10
F
an speed chang
e tap 2 (S003-4)
These s
witches are used to select DC
motor speed of a 4-w
a
y
cassette
type
indoor unit b
y
the taps.
When installing an indoor unit to a high
ceiling surf
ace or when changing the
number of discharge por
ts
, perf
o
rm
setting ref
err
ing to the ne
xt page.
11
Address s
witc
h
This s
witch distinguishes the signal, send
or receiv
e
.
The f
ollo
wing s
witches are pro
vided to the rear
side of the receiving par
t.
F
or setup
, contact
the shop which y
ou purchased the unit.
•
If
“pi, pi
” sound is heard, the MODE lamp of the displa
y lamp goes on, and the
lamp
and
lamp flash alter
nately
, the oper
ation is not perf
or
med with the desired mode
.
8
10
7
9
4
1
5
2
3
1
2
3
4
ON
S003
ON
1
2
3
4
ON
S003
ON
/
432
1
ON
Screw
Clamper
Sensors cover
Sensor P.C. board
Adjust corner cap
Dip switch [S003]
Used in [Trial operation]
Tap 1
Used by selecting [Priority/Secondary]
Tap 2
1
2
3
4
HO
W T
O
SET
THE
F
AN
SPEED
When installing a 4-w
a
y
cassette type indoor unit to high ceiling of a room, the f
an motor speed
can be selected in ag
reement with height of the ceiling and n
umbers of the discharge por
t.
F
or details
, ref
er to the Installation Man
ual f
or 4-w
a
y
discharge cassette type unit.
The f
an motor speed is selected b
y
Dip s
witch [S003] on the sensor P
.C
. board inside or the
adjust cor
ner cap (including sensors) of the ceiling panel of 4-w
a
y
discharge cassette type
indoor unit.
•
After selecting a f
an motor speed, reassemb
le the ceiling
panel as bef
ore
.
Using a clamper
, fix the cab
le connectors with scre
w
s
.
Setup
No.
(0)
(1)
(3)
Installab
le ceiling height (Unit:
m
)
RA
V
-SM560UT
-E
RA
V
-SM800UT
-E
RA
V
-SM1120UT
-E
RA
V
-SM1400UT
-E
4-w
a
y
s
3-w
a
y
s
2-w
a
y
s
4-w
a
y
s
3-w
a
y
s
2-w
a
y
s
4-w
a
y
s
3-w
a
y
s
2-w
a
y
s
2.8
3.2
3.5
3.0
3.3
3.6
3.6
3.9
4.2
3.2
3.5
3.8
3.3
3.5
3.8
3.9
4.1
4.3
3.5
3.8
—
3.6
3.8
—
4.2
4.3
—
T
ap 1
T
ap 2
OFF
OFF
Setting at shipment
OFF
ON
ON
OFF
ACCESSORIES