2 temperature and humidity, 3 storage and shipment, Temperature and humidity -15 – Tandberg Data SDLT 600 User Manual
Page 43: Storage and shipment -15
SDLT 600 Product Manual
Chapter 3: SDLT 600 Tape Drive Specifications
81-81184-02 REV A01
March 2004
3-15
3.3.2 Temperature and Humidity
The ambient operating environment for the tape drive may not exceed the limits shown in
.
(The specifications shown in the table are valid for both the internal and tabletop tape drives.)
3.3.3 Storage and Shipment
The ambient storage and shipment environment for the tape drive may not exceed the limits shown in
. (The specifications shown in the table are valid for both the internal and tabletop tape
drives.)
Table 3-18.
Temperature and Humidity Specification
Specification
Operating Limits
Non-Operating Limits
(Power On, No Tape Loaded)
Wet Bulb Temperature
25 °C (77 °F)
25 °C (77 °F)
Dry Bulb Temperature
Range
10
°
C to 40
°
C (50
°
F to 104
°
F)
10
°
C to 40
°
C (50
°
F to 104
°
F)
Temperature Gradient
11
°
C (20 °F)/hour (across range)
15
°
C (27 °F)/hour (across range)
Relative Humidity
20% to 80% (non-condensing)
10% to 90% (non-condensing)
Humidity Gradient
10%/hour
10%/hour
Table 3-19.
Tape Drive Storage and Shipment Specifications
Specification*
Storage
(Unpacked or Packed)
Shipping
Wet Bulb Temperature
46 °C (114 °F)
46 °C (114 °F)
Dry Bulb Temperature
–40
°
C to 66 °C (–40 °F to 150 °F)
–40 °C to 66 °C (–40 °F to 150 °F)
Temperature Gradient
20 °C (36 °F)/hour (across range)
20 °C (36 °F)/hour (across range)
Relative Humidity
10 to 95% (non-condensing)
10 to 95% (non-condensing)
Humidity Gradient
10%/hour
10%/hour
* Note that these specifications apply to the tape drive only. Media specifications are listed in