Initial start-up checklist – TurboChef Technologies 3240 User Manual
Page 18
This form must be completed in its entirety and submitted to TurboChef to activate the warranty and ensure
proper operation. In the case of a multiple oven installation, a “Start-Up Checklist” form must be completed
for
each oven
, noting its position in the stacked confi guration.
-Scanning/emailing to: [email protected]
-Mailing to: TurboChef
Attn: Warranty Department
4240 International Parkway Suite #105
Carrollton, TX 75007
-Faxing to: 214-379-6085
Before attempting to install the oven, ensure all utilities are complete and ready for fi nal connection and
operation. If any of the requirements listed below are incomplete, notify the responsible party to remedy the
condition. The oven must be fully operational and tested before fi nalizing this document.
You may submit this form by either:
• Gas Volume: Maximum input per cavity 85k BTU
(25kW [Gross])
• Gas Pressure (Nat and LP): 6” W.C. (152.4 mmH
2
O)
(14.94 mb) min, 14” (350.6 mm H
2
O, 34.87 mb) max
Requirements:
• Gas Shut-Off Valve Size: A minimum .75 inch (19.05
mm) I.D. full fl ow valve is required for single ovens.
A minimum 1 inch (25.4 mm) I.D. full fl ow valve is
required for double or triple ovens.
• Ventilation: Operable at the time of this Start-Up
NOTE:
It is the recipient’s responsibility to report to the freight company any concealed or non-concealed
damage. Check the oven, attachments, installation kit, and oven shipping container for damage. The freight
company must be notifi ed of any claims
IMMEDIATELY
.
NOTE:
It is the technician’s responsibility to understand and have available for reference the instructions listed
in the Installation Manual, attached to this form. The manual contains crucial information regarding proper
set-up and operation.
Initial Start-Up Checklist
START-UP
14
Power Specifi cations
Electrical
Gas
-Volume: Maximum input per cavity
85k BTU (25kW [Gross])
-Min. Pressure (Nat, LP, I
2H
, I
2E
, I
2E+
, I
2L
, and I
3P
):
6” W.C. (152.4 mm H2O / 14.94 mb)
-Max. Pressure (Nat, LP, I
2H
, I
2E
, I
2E+
, I
2L
, and I
3P
):
14” W.C. (350.6 mm H2O / 34.87 mb)
-Burner Pressure (Nat, LP, I
2H
, I
2E
, I
2E+
, and I
3P
):
3.5” W.C. (88.9 mm H
2
O / 8.71 mb)
-Burner Pressure (I
2L
):
4.0” W.C. (101.6 mm H
2
O / 9.96 mb)
North America
EU/Asia
Phase
1 Phase
1 Phase
Voltage
208/240 VAC
220-240 VAC
Frequency
50/60 Hz
50/60 Hz
Current Draw
8 Amp
8 Amp
Supply
3 Wire
(L + L + G)
3 Wire
(L + L + G)
Breakers
20 amp
16 amp
Plug
NEMA L620
IEC, 309 3 PIN