START-UP

9. Verify

proper

fl ame rectifi cation.

a. Ensure the oven is in the off or cooling down

mode.

b.

Remove

the

fl ame signal ground wire from the

ignition

module.

c. Connect a DC multipurpose meter that is able

to read micro amps (uA) in series with the fl ame

signal

ground

wire.

i. Connect the red (+) meter lead to the free end

of the fl ame signal ground wire.

ii. Connect the black (-) meter lead to the quick

connect

fl ame signal ground wire terminal on

the ignition module.

d. From the off or cooling down mode, select a

cooking

profi le to operate the oven burner.

e. The reading must be above 1.5 DC uA and it

must be steady.

The oven control system uses basic fl ame rectifi cation

to verify if a fl ame is present. The micro amps must

be greater than 1.5 DC uA. If the reading is below

1.5

DC

uA or is not steady, remove the burner

assembly and investigate the cause. Look for a loose

ignition/sensor wire, or defective sensor assembly.

Follow the troubleshooting steps outlined in the

service

manual.

10. Confi rm all pressure taps have been properly closed

off by performing a soap solution test (see

Connections, pages 10-11). Look for any enlarging

bubbles on all the gas connections. Always adhere

to local gas codes and required methods of leakage

testing in the immediate location (refer to the

regulations in force in the country in which the

appliance is being installed). The prevailing authority

is the local code (or regulations).

11. On the Start-Up Checklist, indicate if the gas

connections passed the soap test.

Ventilation

Performing a ventilation test is required. TurboChef

suggests using a smoke test; however, check with the local

code authority to ensure that no other test is required (re-

fer to the regulations in force in the country in which the

appliance is being installed). The prevailing authority is

the local code (or regulations). Smoke testers are available

through TurboChef. Call 800.90

TURBO

(+1 214-379-6000) for pricing and availability.

1. Perform a smoke test.

a. Turn on the ventilation hood.

b. Turn the oven(s) on.

c. Ready the oven for the smoke test.

i. Select a cooking profi le.

ii. Press the temperature key.

iii. Press and hold the up arrow until the

display reads above 500°F (260°C).

5. Turn the oven on and select a cooking profi le.

During warmup (or while both fan speeds are set to

65%), verify the gas pressure at the main burner

during

100%

fl ame. Take this reading from the

lower tap of the gas valve (fi g. Gas, Steps 4-7). This

tap shows the gas valve’s internal regulator settings.

The maximum operating pressure for natural gas

and propane is 3.5” W.C. (88.9 mmH

2

O, 8.71 mb),

unless operating I

2L

gas — see note below. If needed,

using an 8mm nut driver, adjust the 8mm nut (fi g.

Gas, Steps 4-7) until the manometer reads 3.5” W.C.

(88.9

mmH

2

O, 8.71 mb) unless operating I

2L

gas —

see note below. Turn the 8mm nut driver clockwise

to increase the pressure, or counterclockwise to

decrease the pressure.

NOTE:

The oven operates at the same pressures for all

types of gas, except I

2L

(4” W.C. [101.6 mmH

2

O,

9.96 mb]).

NOTE:

Pressures are factory set and require only minimal

adjustment. Verify oven operation on the display. Con-

fi rm the oven is operating at 100% at the time of the test.
6. Verify the gas pressures at minimum fl ame. This

measurement is taken from the lower tap of the gas

valve while either the red or white wire is

disconnected (page 11, fi g. Gas, Steps 4-7). This tap

will show the gas valve’s internal minimum fl ame

regulator settings. The pressure for both natural gas

and propane is 0.10” W.C. (2.54 mmH

2

O, 0.249

mb). If needed, using a 5mm nut driver, adjust the

5mm nut (page 11, fi g. Gas, Steps 4-7) until the

electronic manometer reads 0.10” W.C. (2.54 mm

H

2

O, 0.249 mb). Reconnect the wire you

disconnected.

NOTE:

To ensure the burner is operating at the mini-

mum fl ame, disconnect the red wire from the modulating

coil of the gas valve (page 11, fi g. Gas, Steps 4-7).
7. Verify the incoming gas pressure (operating). This

is the pressure sent to the oven from the existing

piping system when the oven is operating at 100%

fl ame. Take this reading from the upper tap of the

gas valve (page 11, fi g. Gas, Steps 4-7). This tap will

show the incoming pressure before the regulator

inside the gas valve. The pressures must be no less

than 6” W.C. (152.4 mm H

2

O, 14.94mb)

and no

more than 14” W.C. (350.6 mm H

2

O, 34.87 mb).

CAUTION: A pressure of less than 6” W.C. (152.4

mm

H

2

O, 14.94mb) can cause potential cook

problems.

WARNING: The pressures must be no more than

14” W.C. (350.6 mm H

2

O, 34.87 mb).

Otherwise,

severe damage to the equipment can occur.

8. On the Start-Up Checklist, indicate if any

adjustments were made.