beautypg.com

Group 1 – TOA Electronics C-DR161 CU Series User Manual

Page 21

background image

21

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

16

8

15

7

14

6

13

5

12

4

11

3

10

2

9

1

ALARM IN

IN

RM OUT-B

OUT

IN

G

G

-

-

-

+

+

+

G

G

G

G

G

G

G

G

4

3

2

1

NC

PRIORITY

RM IN-B

CAMERA

TIME SYNC

CONTROL OUT

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

LINK

AUDIO

MONITOR OUT

RS-232C

100BASE-TX

RM IN-A

TERMINATION

ON
OFF

1

IN

OUT

2

1

IN

OUT

DISK ARRAY

2

VIDEO

AC MAINS

1

RM

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

16

8

15

7

14

6

13

5

12

4

11

3

10

2

9

1

ALARM IN

IN

RM OUT-B

OUT

IN

G

G

-

-

-

+

+

+

G

G

G

G

G

G

G

G

4

3

2

1

NC

PRIORITY

RM IN-B

CAMERA

TIME SYNC

CONTROL OUT

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

LINK

AUDIO

MONITOR OUT

RS-232C

100BASE-TX

RM IN-A

TERMINATION

ON
OFF

1

IN

OUT

2

1

IN

OUT

DISK ARRAY

2

VIDEO

AC MAINS

1

RM

C-RF1000

DVR CONTROL

OUTPUT-A

REMOTE

CONTROLLER

INPUT-B

AC adaptor

RM IN-A

RM IN-B

RS-485

RS-485

Group 1

RM
OUT-B

Remote Controller 2
C-RM1000

Interface unit

Termination: OFF

Termination: OFF

Digital Video Recorder 1

C-DR161 Series

Monitor 1

Monitor 2

Live only

To AC Mains

Combination camera

RS-485

RS-485

CAMERA

+ G -

10BASE-T/
100BASE-TX

CONTROL OUT

TIME SYNC

CAMERA

RM IN-B

PRIORITY

NC

1

2

3

4

G

G

G

G

G

G

G

G

+

+

+

-

-

-

G

G

IN

OUT

RM OUT-B

IN

Monitor 2

Live only

RS-485

CAMERA

+ G -

10BASE-T/
100BASE-TX

CONTROL OUT

TIME SYNC

CAMERA

RM IN-B

PRIORITY

NC

1

2

3

4

G

G

G

G

G

G

G

G

+

+

+

-

-

-

G

G

IN

OUT

RM OUT-B

IN

LINK

RM
OUT-B

To next page

Remote Controller 1
C-RM1000

To LAN

To LAN

MONITOR

OUT 2

MONITOR

OUT 2

MONITOR

OUT 1

To AC Mains

Digital Video Recorder 2

C-DR161 Series

MONITOR

OUT 1

Group 1

Master

Monitor

REMOTE CONTROLLER

POWER/DVR

4

3

2

1

INTERFACE UNIT C-RF1000

C-DR091 and C-DR161 Series
C-DR091: 9 I/ O Terminals
C-DR161: 16 I/ O Terminals

*

1

: CPEV-S 0.65-3C (RS-485 Control line)
Twisted pair with shield 22AWG or larger

: Modular cable, 3 m (9.8 ft)
(supplied with the C-RF1000)

: Coaxial cable (Video signal)

*

1

*

1

*

2

*

2

*

2

For the maximum cable length between the C-RF1000
Interface Unit and the C-RM1000 Remote Controller,
refer to C-RM1000 operation manual.

9.3. Digital Video Recorder’s Expansion System (Cascade connection)

Notes
• A cascade-connected system generally requires the Remote Controller(s).
• It is necessary to set DVR-ID in the cascade-connected system. (Refer to

p. 27;

Setting the DVR -ID.)

This manual is related to the following products: