beautypg.com

B. fault codes – Teledyne C-2000 User Manual

Page 87

background image

69

(Rev. 8/04)

®

B. Fault Codes

MagnaStar faults are logged in the Air Radio (ARTU) and are displayed
on the handset as a fault code number. The faults and their associated
display codes are listed below:

Displayed
Fault Code

Description

Fault Code 001

Non-recoverable transceiver fault

Fault Code 002

Over-temperature

Fault Code 004

Synthesizer malfunction

Fault Code 008

OCXO malfunction

Fault Code 016

820 MHz oscillator malfunction

Fault Code 032

20.48 MHz oscillator malfunction

Fault Code 064

Processor fault

Fault Code 128

Load fault

Fault Code 301

Non-recoverable pilot receiver fault

If two or more faults occur at the same time, the handset will display
the sum of the codes; i.e. if the synthesizer unlocked fault and the
OXCO oven failure both occur, then the fault code would read “Fault
Code 012” (8 + 4 = 12).

As long as a fault code is displayed on the MagnaStar handset, the
system will not be fully functional (some functions, such as Inplane
or Satcom calling may still work). Non-recoverable faults (fault codes
that are odd numbers) require that the ARTU power be cycled off for
greater than 15 seconds and then powered back on in order for the
fault to be cleared. Recoverable faults (fault codes that are even num-
bers) may clear themselves a few minutes after hanging up all hand-
sets. If the fault does not clear itself, then cycling the power off for
greater than 15 seconds may still be necessary. If the fault codes can-
not be cleared, the ARTU is defective and needs to be replaced. Please
call 1-888-246-STAR (7827) to order your replacement ARTU.