Performance specifications, Display specifications, 247 specifications appendix a – Omron Programmable Terminals NT631C User Manual
Page 264
247
Specifications
Appendix A
Performance Specifications
Display Specifications
*1: Time taken for brightness to reduce to half at normal temperature and humidity
*2: Sharp brightness adjustment is not available.
Item
Specification
NT631-ST211
@-EV2
NT631C-ST141
@-EV2
NT631C-ST153
@-EV3
Display panel
Display device
EL
(monochrome)
Color STN LCD
(with backlight)
Color TFT high-preci-
sion LCD
(with backlight)
Number of dots (resolution) 640 dots horizontally
× 480 dots vertically
Size of a standard charac-
ter
5.28 mm
5.76 mm
5.28 mm
Effective display area
211 mm horizontally
×
158 mm vertically
(10.4 inches)
229 mm horizontally
×
172 mm vertically
(11.3 inches)
211 mm horizontally
×
158 mm vertically
(10.4 inches)
View angle
(No restriction)
Up/down:
±30°
Left: 55
°
Right: 45
°
Up: 35
°
Down: 65
°
Left: 60
°
Right: 60
°
Display color
Orange, black
(2 colors)
8 colors (and intermediate colors can be dis-
played with tiling patterns)
Life expectancy
30,000 hours min. (until
brightness reduced by
30%)
50,000 hours min.
(until brightness reduced by 50%)
Contrast adjustment
(Not provided)
Adjustable in 100 levels
by operation at the
touch panel
(Not provided)
Backlight
(white cold
cathode tube)
Life expectancy
---
25,000 hours min.
*1
50,000 hours min.
*1
Replacement
---
Can be replaced from
the rear by the user
Cannot be replaced by
the user
Brightness adjustment
(Not provided)
Adjustable in 3 levels by
touch switch operation
at the touch panel
*2
(Not provided)
Automatic turn-off function
Can be set to turn off in 1 to 255 minutes, or to remain on
Indicators
POWER (green LED)
Lit while power is being supplied
RUN
Lit in green: Operating normally, Memory Unit automatic transmission com-
pleted
Flashing in green: Memory Unit automatic transmission being executed,
Memory Unit automatic transmission error
Lit in orange: Low battery voltage (during operation)
Lit in red: Low battery voltage (when operation is stopped)