beautypg.com

Oceanic Watch / Dive Computer GEO User Manual

Page 75

background image

75

VARIABLE ASCENT RATE

Alerts associated with Ascent Rate are based upon 2 sets of speeds which change

at a reference depth of 60 FT (18 M).

WARNING: At depths greater than 60 FT (18 M), Ascent Rates

should not exceed 60 FPM (18 MPM). At depths of 60 FT (18

M) and shallower, Rates should not exceed 30 FPM (9 MPM).

Ascent Rate Warning

At depths deeper than 60 FT (18 M), a Warning (Fig. 67) will be given when

Ascent Rates exceed 50 FPM (15 MPM). The message SLOW > SLOW will scroll

until the Ascent is slowed. At 60 FT (18 M) and shallower, the Warning will be

given when Ascent Rates exceed 25 FPM (7.5 MPM).

Ascent Rate Alarm

At depths deeper than 60 FT (18 M), an Alarm will sound when Ascent Rates

exceed 60 FPM (20 MPM).

At 60 FT (18 M) and shallower, the Alarm will sound when

Ascent Rates exceed 30 FPM (10 MPM).

The Audible will sound, the red LED will flash, and the message

SLOW > SLOW will scroll on/off at the top of the screen. The

Audible and LED will stop when acknowledged with the S

button or when the Ascent is slowed. After acknowledged, the

message SLOW > SLOW will continue to scroll until the Ascent

is slowed below the Alarm rate.

Fig. 67 - ASCENT

WARNING/ALARM