beautypg.com

Oceanic Watch / Dive Computer GEO User Manual

Page 15

background image

15

A single short beep (which cannot be disabled) is emitted for the following -

 Upon completion of a Hot Swap battery change.

 Change from Delayed to Full Violation 5 minutes after the dive.

3 short beeps (which cannot be disabled) are emitted for the following -

 NORM/GAUG Ascent Rate is 51 to 60 FPM (15.1 to 18 MPM) when deeper

than 60 FT (18 M), or 26 to 30 FPM (7.5 to 9 MPM) at 60 FT (18 M) and

shallower.

 FREE Elapsed Dive Time Alarm (3 beeps every 30 seconds if set On).

 FREE Depth Alarms 1/2/3 (set sequentially deeper) - each 3 beeps 3 times.

 FREE TLBG Alarm (Caution zone, 4 segments) - 3 beeps 3 times.

 Entry into Deco during a FREE Dive (Permanent Violation) - 3 beeps 3 times.

 Free Dive Mode Countdown Timer reaches 0:00 - each 3 beeps 3 times.

During the following NORM Dive situations, the 10 second continuous tone will be

followed by a 5 second steady beep that will not turn off when acknowledged -

 Ascending above a required Decompression Ceiling Stop Depth for more

than 5 minutes (referred to as a Delayed Violation).

 Decompression requires a Ceiling Stop Depth of 70 FT (21 M) or deeper.

 Being on the Surface for 5 minutes after a Conditional Violation (Permanent

Violation).

BACKLIGHT

To activate the Backlight - press the L button.

 The Backlight will activate and illuminate the display for button depression

time (10 seconds maximum) plus the user set Duration time of 0, 5, or 10

seconds, for a maximum of 20 seconds.

 Press the button again to activate as desired.