beautypg.com

Oceanic Watch / Dive Computer GEO User Manual

Page 13

background image

13

The Data Download program is used to retrieve Data that was sampled during

dives and stored in the GEO's memory.

The GEO checks for an External Access request once every second while in the

Watch Main Time. Checks are not made if the unit is wet. For a connection to be

made, the Interface Cable is clipped onto the GEO's Data Port and plugged into a

PC USB Port. To establish the connection, the PC program must be running.

When the connection is made, all segments of the LCD appear on the display until

completion of the Upload or Download operation.

 The GEO reverts to the Watch Main Time screen after completion of the

Upload or Download operation, or after 2 minutes if no PC action was taken.

SYMBOLS AND ALPHA NUMERIC GRAPHICS

The upper line of digits on the LCD screen is used to convey alpha Messages such

as Day of the Week, Operating Modes, items being Set, Altitude level, and Alarm

identification. At times, the second line is also used to display alpha numeric

graphics such as FO2 and On/Off. The PO2 values will appear in the lower

line.

AUDIBLE ALARM

Most warning situations that activate the Audible Alarm while operating in NORM

or GAUG Mode cause the GEO to emit 1 beep per second for 10 seconds, or

until the situation is corrected, or it is acknowledged by momentarily pressing and

releasing the S button (less than 2 seconds). After being acknowledged and the

situation corrected, the Alarm will sound again upon reentry into the warning

situation, or entry into another type of warning situation.