beautypg.com

Trouble shooting, No output power or low output – Subaru Robin Power Products RG2800I User Manual

Page 57

background image

– 54 –

6.TROUBLE SHOOTING

No output power or Low output

Engine start

Engine start

Change INV C/U

Resistance value of the stator windings for reference

Surrounding temperature 20

Red

White

Blue

Measured resistance value

Generator

(Refer to the table below)

Measure the resistance value between

Abnormal

Change the alternator

Red-white
White-blue
Red-blue

)

Low or
None

Within the rating

Low or High

Remove the electric
equipment that is connected

Stop the engine, and reset the overload warning

Confirm the engine revolutions
(Turn of the APS switch)
Correct revolution 3550

3650rpm

Go to the engine
malfunction section.
engine check
(refer to p. 56)

RG3200i
RG3200iS

RG2800i
RG2800iS

Wire Color

2.8

4.0

Red – White

Unit: Ohms (

)

0.8

1.1

White – Blue

0.8

1.1

Blue – Red

Voltage Spec.

220, 230, 240

110, 120

110, 120

RG4300i
RG4300iS

2.1

0.8

1.1

2.8

4.0

220, 230, 240

2.1

2.8

4.0

220, 230, 240

2.1

110, 120

0.5

0.5

0.5

Voltage display is :

No

Within the rated range

Out of the
rated range

Overload warning- "O_Load" is displayed

Yes

This manual is related to the following products: