background image

4

DANGER: Indicates the presence of immediate hazards which will cause severe person-

al injury, death or substantial property damage if ignored.

WARNING: Indicates the presence of hazards or unsafe practices which could cause

severe personal injury, death or substantial property damage if ignored.

CAUTION: Indicates the presence of hazards or unsafe practices which could cause

minor personal injury or product or property damage if ignored.

NOTE:

Indicates special instructions on installation, operation, or maintenance which

are important but not related to personal injury hazards.

DANGER: Make sure the gas on which the heater

will operate is the same type as that specified on the

heater rating plate.

WARNING: Should overheating occur or the gas

supply valve fail to shut, do not turn off or disconnect

the electrical supply to the heater. Instead, shut off

the gas supply at a location external to the heater.

WARNING: Do not use this heater if any part has

been under water. Immediately call a qualified

service technician to inspect the heater and to

replace any part of the control system and any gas

control which has been under water.

WARNING: To minimize the possibility of improper

operation, serious personal injury, fire, or damage to

the heater:

Always keep the area around the heater free of

combustible materials, gasoline, and other flam-

mable liquids and vapors.

Heater should never be covered or have any

blockage to the flow of fresh air to the heater.

WARNING - CALIFORNIA PROPOSITION

65: This product contains chemicals known to the

State of California to cause cancer, birth defects or

other reproductive harm.

WARNING: Risk of electrical shock. More than one

disconnect switch may be required to deenergize the

equipment before servicing.

CAUTION: Operation of this heater in low-

temperature systems requires special piping.

Harmful internal condensation will occur if the inlet

water temperature does not exceed 105°F. Warranty

claims will be denied when condensation occurs.

CAUTION: If this heater is to be installed above

radiation level, it must be provided with a low water

cut-off device at the time of heater installation.

CAUTION: If this heater is to be installed in a

negative or positive pressure equipment room, there

are special installation requirements. Consult factory

for details.

WARNINGS

Pay Attention to These Terms

This manual is related to the following products: