beautypg.com

Winterizing your heater – Raypak RAYTHERM P-926 User Manual

Page 31

background image

31

Winterizing Your Heater

When heaters installed outdoors in freezing climate

areas are to be shut down for the winter, please

observe the following step-by-step procedure:

1. Remove the drain plug or open the drain cock

located on the inlet-outlet header. On larger

heaters with external Unitherm Governor(s) and

piping, locate plug at low point of Governor piping,

or break connections and rotate inlet fittings 180

degrees to face downward. Turn off manual main

gas and main gas shut off.

2. Disconnect compression fittings on both ends of

the 1/8" copper tube and allow the tube to drain.

Remove the "heat exchanger inspection panels"

on the right side of the heater to gain access to the

fitting on the return header. Remove return head-

er.