Regency FG39 FireGenie Freestanding Gas Stove

9

INSTALLATION

FLUEING ARRANGEMENTS

Vertical Terminations Using

Dura-Flue Fluing System for

Residential Manufactured and Mobile Homes

The shaded area in the diagram below shows all allowable

combinations of straight vertical and offset to vertical runs

with vertical terminations. Maximum two 45

o

elbows.

If the flue is ENCLOSED in a chase (min. size 9" x 9" / 229mm x 229mm)

maintain a 1-1/4" (32mm) clearance to combustibles.

May be installed in Manufactured (Mobile) Homes after first sale.

Horizontal Terminations for All Fluing Systems

The shaded areas in the diagram below show all allowable

combinations of vertical runs with horizontal terminations.

Maximum one 90

O

elbow (two 45

o

elbows equal one 90

o

elbow).

LPG and NG:

Residential, Manufactured and Mobile Homes

Installations

The fluing arrangements diagrammed below, have a min. of 75% (flue

loss) efficiency with Fan Off, as required for manufactured homes.

(Actual efficiency may be as high as 85%)

May be installed in Manufactured (Mobile) Homes after first sale.

Flue Restrictor Position

To set the Flue restriction as indicated in the diagram, simply loosen the

screws and push the flue restrictor plate to the correct position. Tighten

the screws.

Flue Restrictor setting at

40 Mj/h

Flue Restrictor setting at

31 Mj/h