beautypg.com

Maintenance, Fan maintenance – Regency FIREGENIE FG39-NG User Manual

Page 28

background image

28

Regency FG39 FireGenie Freestanding Gas Stove

MAINTENANCE

FAN MAINTENANCE

If your fan requires maintenance or replace-

ment, access to the fan is through the plate on

the rear wall of the firebox. NOTE: the unit

MUST NOT be operated without the fan

access panel securely in place and cor-

rectly sealed.

If the fan is damaged or needs repair, it

shall be repaired by the manufacturer or

its service agent or similiarily qualified

person to avoid a hazard.

IMPORTANT: These fans collect a lot of

dust from within your home. En-

sure you maintain these fan mo-

tors on a regular basis by vacuum-

ing out the fan squirrel cages,

around the motor, and around the

grills on the back of the stove.

Alternate Fan Access:

If the rear access cover is

accessible, it can be removed

to provide access to the fan.

IMPORTANT

Disconnect power supply

before servicing

WARNING:

Electrical Grounding Instructions

This appliance is equipped with a

three pronged (grounding) plug

for your protection against shock

hazard and should be plugged

directly into a properly grounded

three-prong receptacle. Do not cut

or remove the grounding prong

from this plug.

7) Tighten side panels nuts using the following

procedure:

a. tighten top & bottom outside corner nuts

(2)

b. tighten inside nuts (3)

c. tighten top & bottom inside corners (2)

8) Tighten the 10 nuts on center glass retainer.

9) Repeat step 7 for other side panel.

10) Replace new gasket by gluing it in place.

11) Install door onto stove and check the seal.

Fan Removal

1) Unplug or disconnect power source to

stove.

2) Remove all logs and the rear log support,

then remove the 10 screws holding the

access panel in place.

3) Unclip the black and white wires from the

fan motor.

4) Open both side doors and gently pull the

flex pipe away from the center, otherwise

the fan can catch on the flex pipe during

installation and tear the pipe. Do not tear or

damage the flex pipe.

5) Lift fan off of the 2 pins, tip back and pull

through firebox opening. Disconnect the

green ground wire from the right side of the

fan as soon as you can reach it.

Fan Replacement

Reverse the above steps (1 - 5). If necessary

install a new gasket before replacing the fan

access panel. Make sure the fan wires and the

ground wire are reattached.

Hint for pushing fan down onto pins - rub a bit

of dish soap on the grommet so it will slide more

easily onto the pin. Check to make sure the fan

is seated properly on the pins - try to move the

fan back and forth, there should be no noise,

if there is check that the grommets haven't

come loose.

This manual is related to the following products: