beautypg.com

Installation, Log set installation, Conversion to lower btu rating – Regency FIREGENIE FG39-NG User Manual

Page 19

background image

Regency FG39 FireGenie Freestanding Gas Stove

19

LOG SET

INSTALLATION

Read the instructions below carefully

and refer to the diagrams. If logs are

broken do not use the unit until they are

replaced. Broken logs can interfere with

the pilot operation.

The gas log kit contains the following:

a) 02-65 Rear Log

b) 02-56 Middle Left Log

c) 02-44 Front Left Log

d) 02-46 Left Top Log

e ) 02-45 Front Right Log

f) 02-47 Center Log

g) 02-48 Middle Right Log

h)

Embers

i)

Lava

Note: Install Optional Brick Panels prior

to installing logs.

Embers.

Embers

The "02" refer numbers (i.e. 02-65) are

molded into the rear of each log.

1) Carefully remove the logs from the box and

unwrap them. The logs are fragile, handle

with care - do not force into position.

2) Sprinkle the embers on the left and right

sides of the firebox base.

INSTALLATION

CONVERSION TO LOWER BTU RATING

THIS CONVERSION MUST BE DONE BY AN AUTHORIZED

GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION

!!

NG Conversion Kit 730-920

Contains:

Qty. Part # Description

1 904-240 Burner Orifice #37 (NG)

1 918-034 Decal "Converted to 30,000 Btu"

1 918-033 Instruction Sheet

LPG Conversion Kit 730-922

Contains:

Qty. Part # Description

1 904-390 Burner Orifice #52 (LPG)

1 918-034 Decal "Converted to 30,000 Btu"

1 918-033 Instruction Sheet

Additional Piece (pkg. with unit:

1

Log Bracket Restrictor

1) Shut off the gas supply.

2) Open the front door. Carefully remove the

logs and lava rock.

3) Remove burner. See diagram below.

Burner Orifice

4) Unscrew the 2 Rear

Log Pins and move

to the front hole po-

sition.

5) Remove Rear Log

Bracket and slide the

Log Bracket Re-

strictor between the

Position the Log Bracket Restrictor between

the Rear Log Bracket and the burner.

6) Remove burner orifice with a 1/2" spanner

and discard.

7) Reinstall new burner orifice (NG stamped

#37 or LPG stamped #52) and tighten.

8) Reverse steps 3) and 2).

9) Adjust Flue restrictor setting: To set the Flue

restriction as indicated in the diagram, sim-

ply loosen the screws and push the flue

restrictor plate to the correct position. Tight-

en the screws.

Unit Btu/h

Restrictor Opening

FG3940 Mj/h

A 45mm

31 Mj/h

B 35mm

Note: Use a

magnetic type

screwdriver if

possible.

Rear Log Bracket and the burner, secure

with the 2 screws.

Flue Restrictor

setting at High Btu/h

Flue Restrictor

setting at Low Btu/h

10) Attach the label "This unit has been con-

verted to..." on top of the data badge over

the higher Btu information.

11) Check for gas leaks.

12) Check inlet and outlet pressures.

13) Check operation of flame control. Check for

proper flame appearance and glow on logs.

This manual is related to the following products: