beautypg.com

Saving mc-09 data on an external midi sequencer, Bulk dump (p. 65) – Roland MC-09 User Manual

Page 65

background image

65

Connecting external MIDI devices

10. Press the [INC] or [DEC] button until the display

indicates “

”(OFF).

With these settings, the MC-09 will receive MIDI messages
from your computer, and the DSP synthesizer (pattern tone/
rhythm set) will sound.

11. Press the [SETUP] button to complete the settings.

Saving the MC-09 settings to
an external sequencer (Bulk
Dump)

Data for the currently selected pattern, process patch or all
saved settings, can be transmitted to an external MIDI
device. This function is called

bulk dump

. You can create a

backup of the MC-09’s data by using bulk dump to record
the data on an external MIDI sequencer. You can also use this
function to replicate the current settings of one MC-09
(except for the Loop setting) on another MC-09.

Saving MC-09 data on an
external MIDI sequencer

1. Use a MIDI cable to connect the MC-09’s MIDI OUT to

the MIDI IN of your external MIDI sequencer.

2. Press the [SETUP] button.

3. Press the [INC] or [DEC] button until the display

indicates “

”(Bulk Dump).

4. Press the [ENTER] button.

5. Use the [INC] and [DEC] buttons to select the data that

you want to save.

:

Settings for the currently selected pattern

:

Process patches

:

All patterns, process patches, and system

settings

6. Press the [ENTER] button.

The display will blink “

”(Sure), asking you to

confirm the operation.

If you decide to cancel, press the [EXIT] button.

7. Begin recording on your external MIDI sequencer.

8. Press the [ENTER] button to initiate the bulk dump.

While the data is being transmitted, the indication in the
display will blink. When transmission is completed, the

display will show

.

9. Stop recording on your external MIDI sequencer.

10. Press the [EXIT] button to complete the bulk dump.

Restoring MC-09 data from an
external MIDI sequencer

The data that was saved by a bulk dump is referred to as

bulk data

. By loading this bulk data, you can reproduce the

state in which the MC-09 was when it transmitted the bulk
data.

1. Use a MIDI cable to connect the MC-09’s MIDI IN to

the MIDI OUT of the external MIDI sequencer.

2. Press the [SETUP] button.

3. Press the [INC] or [DEC] button until the display

indicates “

”(Bulk Receive).

4. Press the [ENTER] button.

The MC-09 will wait to receive bulk data.

If you decide to cancel, press the [EXIT] button.

5. Play back your external MIDI sequencer to transmit the

bulk data to the MC-09.

While the MC-09 is receiving bulk data, the display will
blink.

When bulk data reception ends, the display will indicate

”. This display will continue for approximately 60

seconds.

* Never turn off the power while “

” appears in the

display. Doing so will damage the data in the memory card
and internal memory.

* You must transmit all of the bulk data.

6. Press the [EXIT] button to complete the operation, after

the display indicates “

”.