beautypg.com

RoyalTek REB-3000 User Manual

Page 34

background image

RoyalTek RGM-3000/REB-3000
GPS Module Operational Manual)

29

following example: Sets the receiver into

low power Modes. Example: Set receiver

into Trickle Power at 1 hz update and 200

ms On Time.

A0A20009—Start Sequence and Payload

Length

97000000C8000000C8—Payload

0227B0B3—Message Checksum and End

Sequence

Table 38 Set Trickle Power Parameters I.D. 151

Binary(Hex)

Name

Bytes

Scale Example

Units

Description

Message ID

1

97

ASCII 151

Push To FixMode

2

0000

ON=1, OFF=0

Duty Cycle

2

*10

00C8

%

% Time on

Milli Seconds On
Time

4

000000C8 ms

Range 200 ~ 500 ms

Payload Length: 9bytes.

Computation of Duty Cycle and On

Time.

The Duty Cycle is the desired time to be

spent tracking.The On Time is the duration

of each tracking period (range is 200 - 900

ms). To calculate the TricklePower update

rate as a function of Duty cycle and On

Time, use the following formula:

Off Time = (On Time - (Duty Cycle * On

Time)) / Duty Cycle

Update rate = Off Time + On Time

Note –

On Time inputs of > 900 ms will

default to 1000 ms

Following are some examples of

selections:

Table 39 Example of selections for Trickle Power Mode of Operation

Mode

On Time (ms)

Duty Cycle (%)

Update rate (1/Hz)

Continuous 1000

100

1

Trickle Power

200

20

1

Trickle Power

200

10

2

Trickle Power

300

10

3

Trickle power

500

5

10

See Table 40 for supported/unsupported settings.

Table 40 Trickle Power Mode Settings

Update Rate (second)

On
Time
(ms)

1 2 3 4 5 6 7 8

200

Y Y N N N N N N

300

Y Y Y Y Y Y N N

400

Y Y Y Y Y Y Y Y

500

Y Y Y Y Y Y Y Y

600

Y Y Y Y Y Y Y Y

700

Y Y Y Y Y Y Y Y

800

Y Y Y Y Y Y Y Y

900

Y Y Y Y Y Y Y Y

Y = Yes (Mode supported)

N = No (Mode NOT supported)

This manual is related to the following products: