Table 12 Query/Rate Control Data
Format(See example 1.)
1.Quety the GGA message with checksum
enabled: $PSRF103,00,01,00,01*25
2.Enable VTG message for a 1 Hz
constant output with checksum enabled:
$PSRF103,05,00,01,01*20
3.Disable VTG message
$PSRF103,05,00,00,01*21
Table 12
Query/Rate Control Data Format(See example 1.)
Name
Example
Units
Description
Message ID
$PSRF103
PSRF102 protocol header
Message
00
See Table 13
Mode
01
0=Set Rate, 1=Query
Rate
00
seconds Output – off=0,max=255
Cksum Enable
01
0=Disable Checksum, 1=Enable Checksum
Checksum *25
End of message termination
Table 13
Messages
Value Description
0 GGA
1 GLL
2 GSA
3 GSV
4 RMC
5 VTG
LLA Navigation Initialization
This command is used to initialize the
module for a warm start , by providing
current position(in latitude, longitude, and
altitude coordinates), clock offset, and time.
This enables the receiver to search for the
correct satellite signals at the correct signal
parameters . Correct initialization
parameters enable the receiver to acquire
signals quickly.
Table 14 contains the input values for the
following example: Start using known
position and time $PSRF104, 37.3875111,
-121.97232, 0, 95000, 237759, 922, 12,
3*3A
Table 14
LLA Navigation Initialization Data Format
Name
Example
Units
Description
Message ID
$PSRF104
PSRF104 protocol header
Lat
37.3875111
Degrees
Latitude position (Range 90 to –90)
Lon
-121.97232
Degrees
Longitude position (Range 180 to –180)
Alt 0
Meters
Altitude
position
CLK Offset
95000
Hz
Clock Offset of the Evaluation Unit1
Time Of Week
237759
Seconds
GPS Time Of Week
Week No
922
GPS Week Number
Channel Count
12
Range 1 to 12
Reset Cfg
3
See Table 15
Checksum *3A
End of message termination
Use 0 for last saved value if available. If this is unavailable, a default value of 96,000 will be used.
Table 15
Reset Configuration
Hex Description
0x01
Data Valid – Warm /Hot Starts=1
0x02
Clear Ephemeris – Warm Start=1